INTEGRATED-ALL SOLID ELECTRODES pH SENSOR PERFORMANCE DEPENDENCY ON SILVER/SILVER CHLORIDE ELECTRODE THICKNESS

Environmental monitoring, biomedical research, and food processing require precise pH measurements; hence pH sensors are important. The glass-based reference electrode (RE) is the most common pH sensor but the fragility of the glass-based RE prevents it from being miniaturized. Thus, an integrated-all solid electrode (IASE) was fabricated where the Ag layer was thermally evaporated, followed by a chlorination process to form an Ag/AgCl RE, and a titanium dioxide (TiO2) thin film was used as the sensing electrode (SE) to form the integrated-all solid electrode (IASE). The influence of silver/silver chloride (Ag/AgCl) thin film electrode thickness (60, 120, 180, 240, and 300 nm) on the electrochemical-based pH sensor was studied. The IASE was applied as the extended-gate of field effect transistor (EGFET). The pH sensor sensitivity and linearity were evaluated for the IASE performance. As a result, the thicker the Ag/AgCl layer the higher the sensitivity. The 300 nm Ag/AgCl thickness showed promising sensitivity and linearity with 67.8 mV/pH and 0.9846, respectively.

Authors

Institutions

Publication Details

Journal
Jurnal Teknologi
Published
2025-06-13
DOI
https://doi.org/10.11113/jurnalteknologi.v87.22362
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INTEGRATED-ALL SOLID ELECTRODES pH SENSOR PERFORMANCE DEPENDENCY ON SILVER/SILVER CHLORIDE ELECTRODE THICKNESS

Norhidayatul Hikmee Mahzan, Sukreen Hana Herman, Zurita Zulkifli, Aimi Bazilah Rosli et al.
Jurnal Teknologi
Analytical Chemistry and Sensors
article

INTEGRATED-ALL SOLID ELECTRODES pH SENSOR PERFORMANCE DEPENDENCY ON SILVER/SILVER CHLORIDE ELECTRODE THICKNESS

Norhidayatul Hikmee Mahzan, Sukreen Hana Herman, Zurita Zulkifli, Aimi Bazilah Rosli, Z. Nurbaya, Shaiful Bakhtiar Hashim
article en

Abstract

Environmental monitoring, biomedical research, and food processing require precise pH measurements; hence pH sensors are important. The glass-based reference electrode (RE) is the most common pH sensor but the fragility of the glass-based RE prevents it from being miniaturized. Thus, an integrated-all solid electrode (IASE) was fabricated where the Ag layer was thermally evaporated, followed by a chlorination process to form an Ag/AgCl RE, and a titanium dioxide (TiO2) thin film was used as the sensing electrode (SE) to form the integrated-all solid electrode (IASE). The influence of silver/silver chloride (Ag/AgCl) thin film electrode thickness (60, 120, 180, 240, and 300 nm) on the electrochemical-based pH sensor was studied. The IASE was applied as the extended-gate of field effect transistor (EGFET). The pH sensor sensitivity and linearity were evaluated for the IASE performance. As a result, the thicker the Ag/AgCl layer the higher the sensitivity. The 300 nm Ag/AgCl thickness showed promising sensitivity and linearity with 67.8 mV/pH and 0.9846, respectively.

Jurnal TeknologiVol. 87(4)
Universiti Teknologi MARA (MY)
Openalex Percentile: Top 82%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.