VERIFICATION TESTING OF A WELL-MATCHED WIND TURBINE POWER GENERATION SYSTEM

Due to Malaysia's typically low and fluctuating wind speeds, it is crucial to carefully select and match appropriate wind turbine generators to ensure efficient power production. However, the data provided by manufacturers for wind turbine generators often differs from actual operational performance. This study aims to develop a test rig and setup to characterize the generator constant. The verification testing involved validating a 1kW generator with a rated voltage of 48V and a rated RPM of 380 under both unloaded and loaded power systems. The results showed that the calculated generator constant (Kv) for the 1kW 48V generator was 4.56 rpm/V when the system was unloaded. When the system starts charging, using an Energy Storage Capacity (ESC) of 4.8kWh, the Kv value increased to 63.13 rpm/V. The maximum charging power (Pc) that could be generated under these conditions was 944W at 533 rpm. According to the results, at the generator's rated RPM of 380, the maximum charging power attainable is 608W. This test result contradicts the manufacturer's claim that at a rated RPM of 350, the power output is 1kW.

Authors

Institutions

Publication Details

Journal
Jurnal Teknologi
Published
2025-06-13
DOI
https://doi.org/10.11113/jurnalteknologi.v87.22893
Primary Topic
Real-time simulation and control systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VERIFICATION TESTING OF A WELL-MATCHED WIND TURBINE POWER GENERATION SYSTEM

Kamarulafizam Ismail, Fazila Mohd Zawawi, Mohamad Isamuddin Majunit, Najah Saidah Ahmad Bakhari
Jurnal Teknologi
Real-time simulation and control systems
article

VERIFICATION TESTING OF A WELL-MATCHED WIND TURBINE POWER GENERATION SYSTEM

Kamarulafizam Ismail, Fazila Mohd Zawawi, Mohamad Isamuddin Majunit, Najah Saidah Ahmad Bakhari
article en

Abstract

Due to Malaysia's typically low and fluctuating wind speeds, it is crucial to carefully select and match appropriate wind turbine generators to ensure efficient power production. However, the data provided by manufacturers for wind turbine generators often differs from actual operational performance. This study aims to develop a test rig and setup to characterize the generator constant. The verification testing involved validating a 1kW generator with a rated voltage of 48V and a rated RPM of 380 under both unloaded and loaded power systems. The results showed that the calculated generator constant (Kv) for the 1kW 48V generator was 4.56 rpm/V when the system was unloaded. When the system starts charging, using an Energy Storage Capacity (ESC) of 4.8kWh, the Kv value increased to 63.13 rpm/V. The maximum charging power (Pc) that could be generated under these conditions was 944W at 533 rpm. According to the results, at the generator's rated RPM of 380, the maximum charging power attainable is 608W. This test result contradicts the manufacturer's claim that at a rated RPM of 350, the power output is 1kW.

Jurnal TeknologiVol. 87(4)
Newcastle University Medicine Malaysia (MY), University of Technology Malaysia (MY)
Openalex Percentile: Top 85%
Real-time simulation and control systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

VERIFICATION TESTING OF A WELL-MATCHED WIND TURBINE POWER GENERATION SYSTEM — Kamarulafizam Ismail, Fazila Mohd Zawawi, et al. · Jurnal Teknologi (2025) | TGRS Research Map | TGRS