Tracking orthodontic tooth movement and associated biomechanics using an integrated clinical and in vitro mechanical approach

The objective of this study was to establish an integrated clinical and in vitro experimental approach to track tooth positions and replicate digital tooth positions in vitro for biomechanical load measurement over orthodontic treatment. Patients between 11-14years were recruited to collect four digital intraoral scans in 4-6-week intervals. Patients were treated for mild anterior crowding using 0.022’’ Damon Q2 brackets and CuNiTi round archwires sized up at each treatment interval (T1-T2: 0.014’’, T2-T3: 0.016’’, T3-T4: 0.018’’). Scans were superimposed and clinical tooth movement was tracked using bracket-slot midpoint position differences. An in-house workflow was developed using MATLAB and SolidWorks to replicate digital bracket positions on an Orthodontic Simulator (OSIM) with custom-dimensioned jigs. Mechanical experiments for the sample arches were performed at 37°C for 3D force measurements at each tooth upon wire insertion (n=5/archwire size). The average superimposition error between T2-T4 and T1 scans was 0.19mm. Average errors in bracket position replication across all directions was 0.41mm in the local X-, Y-, and Z-direction, respectively. The initial force and tooth movement range was 0.00-1.43N and 0.01-1.81mm in the Y-direction, and 0.01-2.17N and 0.00-1.45mm in the Z-direction. Tooth movement ranged from 0.00-0.30 mm/week in the Y-direction and 0.00-0.24 mm/week in the Z-direction over treatment. This study developed a process to measure clinical tooth movement and existing force/moment systems for sample arches over orthodontic braces treatment. Future work will involve an expanded data set to establish fundamental relationships between force systems and clinical tooth movements.

Authors

Institutions

Publication Details

Journal
Biomedical Engineering Advances
Published
2025-06-13
DOI
https://doi.org/10.1016/j.bea.2025.100186
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tracking orthodontic tooth movement and associated biomechanics using an integrated clinical and in vitro mechanical approach

Lingyu Bu, Paul W. Major, Dan L. Romanyk, Manuel O. Lagravère et al.
Biomedical Engineering Advances
Orthodontics and Dentofacial Orthopedics
article

Tracking orthodontic tooth movement and associated biomechanics using an integrated clinical and in vitro mechanical approach

Lingyu Bu, Paul W. Major, Dan L. Romanyk, Manuel O. Lagravère, Arya Subramanian, Robyn de Wet
article en

Abstract

The objective of this study was to establish an integrated clinical and in vitro experimental approach to track tooth positions and replicate digital tooth positions in vitro for biomechanical load measurement over orthodontic treatment. Patients between 11-14years were recruited to collect four digital intraoral scans in 4-6-week intervals. Patients were treated for mild anterior crowding using 0.022’’ Damon Q2 brackets and CuNiTi round archwires sized up at each treatment interval (T1-T2: 0.014’’, T2-T3: 0.016’’, T3-T4: 0.018’’). Scans were superimposed and clinical tooth movement was tracked using bracket-slot midpoint position differences. An in-house workflow was developed using MATLAB and SolidWorks to replicate digital bracket positions on an Orthodontic Simulator (OSIM) with custom-dimensioned jigs. Mechanical experiments for the sample arches were performed at 37°C for 3D force measurements at each tooth upon wire insertion (n=5/archwire size). The average superimposition error between T2-T4 and T1 scans was 0.19mm. Average errors in bracket position replication across all directions was 0.41mm in the local X-, Y-, and Z-direction, respectively. The initial force and tooth movement range was 0.00-1.43N and 0.01-1.81mm in the Y-direction, and 0.01-2.17N and 0.00-1.45mm in the Z-direction. Tooth movement ranged from 0.00-0.30 mm/week in the Y-direction and 0.00-0.24 mm/week in the Z-direction over treatment. This study developed a process to measure clinical tooth movement and existing force/moment systems for sample arches over orthodontic braces treatment. Future work will involve an expanded data set to establish fundamental relationships between force systems and clinical tooth movements.

Biomedical Engineering AdvancesVol. 10
University of Alberta (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 86%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.