Study of Dynamic Fields in an Enclosure with Two Openings Heated by a Cylindrical Heat Source

The objective of this work is to understand and predict the gas flows generated in an enclosure with an aspect ratio H/L= 0.83, having 02 openings located at the floor level and heated by a linear solid heat source. 02 enclosures Case 23 and Case 21 were studied. In these enclosures the openings are symmetrical and of the same sections. In the enclosure Case 23, the heat source is 3 mm above the floor and located at the position x+ = 0. In the enclosure Case 21, the heat source is at the position x+ = 0.24. The numerical computations of the velocity fields, pressure fields and mass flow rates will be carried out using the Direct Numerical Simulation (DNS) method and considering that a constant temperature is initially imposed on the heat source, that the enclosure is in thermal equilibrium with the outside and that there is no movement of gases at the openings. The results show that in the Case 23 enclosure, the velocity plume is turbulent and centered while in the Case 21 enclosure the velocity plume is strongly deflected near the side wall located at x+ = 0.5. This deviation can be due to the Couanda effect. In the Case 23 and Case 21 enclosures, we observe on each opening an incoming mass flow of fresh air and an outgoing mass flow of hot gases. Part of the hot gas flows descending towards the floor of the enclosures exits the enclosure and the other part is entrained by the velocity plume. The numerical computations of differential static pressure show that near the floor the values of differential static pressure are negative and outside the vicinity of the floor they are positive and increase with the height of the enclosure. The static pressure profiles have the same appearance. The comparisons of the static pressure profiles obtained in the Case 23 enclosure with the results of the literature are consistent.

Authors

Institutions

Publication Details

Journal
European Journal of Engineering and Technology Research
Published
2025-05-24
DOI
https://doi.org/10.24018/ejeng.2025.10.3.3258
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Dynamic Fields in an Enclosure with Two Openings Heated by a Cylindrical Heat Source

Christian Anicet Koueni Toko
European Journal of Engineering and Technology Research
Fire dynamics and safety research
article

Study of Dynamic Fields in an Enclosure with Two Openings Heated by a Cylindrical Heat Source

Christian Anicet Koueni Toko
article en

Abstract

The objective of this work is to understand and predict the gas flows generated in an enclosure with an aspect ratio H/L= 0.83, having 02 openings located at the floor level and heated by a linear solid heat source. 02 enclosures Case 23 and Case 21 were studied. In these enclosures the openings are symmetrical and of the same sections. In the enclosure Case 23, the heat source is 3 mm above the floor and located at the position x+ = 0. In the enclosure Case 21, the heat source is at the position x+ = 0.24. The numerical computations of the velocity fields, pressure fields and mass flow rates will be carried out using the Direct Numerical Simulation (DNS) method and considering that a constant temperature is initially imposed on the heat source, that the enclosure is in thermal equilibrium with the outside and that there is no movement of gases at the openings. The results show that in the Case 23 enclosure, the velocity plume is turbulent and centered while in the Case 21 enclosure the velocity plume is strongly deflected near the side wall located at x+ = 0.5. This deviation can be due to the Couanda effect. In the Case 23 and Case 21 enclosures, we observe on each opening an incoming mass flow of fresh air and an outgoing mass flow of hot gases. Part of the hot gas flows descending towards the floor of the enclosures exits the enclosure and the other part is entrained by the velocity plume. The numerical computations of differential static pressure show that near the floor the values of differential static pressure are negative and outside the vicinity of the floor they are positive and increase with the height of the enclosure. The static pressure profiles have the same appearance. The comparisons of the static pressure profiles obtained in the Case 23 enclosure with the results of the literature are consistent.

European Journal of Engineering and Technology ResearchVol. 10(3)
University of Maroua (CM)
Openalex Percentile: Top 84%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.