Determination of Selenium in Polyheteroatomic Organic Compounds Using Atomic Emission Spectrometry with Microwave Plasma

A method for determining selenium as a macroelement of synthetic polyheteroatomic organic compounds using atomic emission spectrometry with microwave plasma (MP-AES) is developed. The objects of analysis are mainly various selenodiazole derivatives. Optimal conditions for sample preparation and atomic emission determination of selenium are found. To mineralize the substances under study, combustion in a flask filled with oxygen with the addition of potassium nitrate, which improves the combustion process and prevents the formation of soot, is used. Hydrochloric acid with a concentration of 0.1 M is used as an absorption solution. It is noted that before starting measurements, it is necessary to purge the monochromator and optimize the pressure in the atomic emission spectrometer nebulizer. Under the obtained conditions, the performance characteristics of the method are evaluated: the limits of detection and quantitative determination of selenium (0.2 and 0.6 mg/L, respectively), intralaboratory precision, and correctness. Using the developed method, 11 synthetic organic compounds are analyzed with a selenium content from 12 to 51%; the absolute error of the analysis does not exceed 0.3%, which meets the requirements for organic elemental analysis.

Authors

Institutions

Publication Details

Journal
Inorganic Materials Applied Research
Published
2024-12-01
DOI
https://doi.org/10.1134/s2075113325700108
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Selenium in Polyheteroatomic Organic Compounds Using Atomic Emission Spectrometry with Microwave Plasma

Vera D. Tikhova, Svetlana Yu. Petrakova
Inorganic Materials Applied Research
Analytical chemistry methods development
article

Determination of Selenium in Polyheteroatomic Organic Compounds Using Atomic Emission Spectrometry with Microwave Plasma

Vera D. Tikhova, Svetlana Yu. Petrakova
article en

Abstract

A method for determining selenium as a macroelement of synthetic polyheteroatomic organic compounds using atomic emission spectrometry with microwave plasma (MP-AES) is developed. The objects of analysis are mainly various selenodiazole derivatives. Optimal conditions for sample preparation and atomic emission determination of selenium are found. To mineralize the substances under study, combustion in a flask filled with oxygen with the addition of potassium nitrate, which improves the combustion process and prevents the formation of soot, is used. Hydrochloric acid with a concentration of 0.1 M is used as an absorption solution. It is noted that before starting measurements, it is necessary to purge the monochromator and optimize the pressure in the atomic emission spectrometer nebulizer. Under the obtained conditions, the performance characteristics of the method are evaluated: the limits of detection and quantitative determination of selenium (0.2 and 0.6 mg/L, respectively), intralaboratory precision, and correctness. Using the developed method, 11 synthetic organic compounds are analyzed with a selenium content from 12 to 51%; the absolute error of the analysis does not exceed 0.3%, which meets the requirements for organic elemental analysis.

Inorganic Materials Applied ResearchVol. 15(6)
Novosibirsk Institute of Organic Chemistry (RU)
Openalex Percentile: Top 72%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.