Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals

The wavelength and system-resolution dependencies of dynamic optical coherence tomography (DOCT) are investigated experimentally and numerically. Experimental investigations demonstrate significant wavelength dependency for the DOCT values but no marked resolution dependency. Numerical simulations were performed using diffusion, random-ballistic motion, and mono-directional flow-based motion models. Diffusion and random-ballistic motion-based simulations show significant wavelength dependency. Additionally, these simulations revealed a small but certain resolution dependency. Mono-directional flow simulations did not show wavelength dependency but did demonstrate resolution dependency. The DOCT value is sensitive to both tissue dynamics and the OCT system specification. These effects should be considered when interpreting DOCT images.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-06-13
DOI
https://doi.org/10.1364/boe.564030
Citations
1
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals

Atsuko Furukawa, Thitiya Seesan, Rion Morishita, Yoshiaki Yasuno et al.
1 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
0.67
article

Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals

Atsuko Furukawa, Thitiya Seesan, Rion Morishita, Yoshiaki Yasuno, Yiheng Lim, Lida Zhu, Shuichi Makita, Pradipta Mukherjee, Yuanke Feng, Satoshi Matsusaka, Ibrahim Abd El-Sadek, Shumpei Fujimura
article en
1 citations

Abstract

The wavelength and system-resolution dependencies of dynamic optical coherence tomography (DOCT) are investigated experimentally and numerically. Experimental investigations demonstrate significant wavelength dependency for the DOCT values but no marked resolution dependency. Numerical simulations were performed using diffusion, random-ballistic motion, and mono-directional flow-based motion models. Diffusion and random-ballistic motion-based simulations show significant wavelength dependency. Additionally, these simulations revealed a small but certain resolution dependency. Mono-directional flow simulations did not show wavelength dependency but did demonstrate resolution dependency. The DOCT value is sensitive to both tissue dynamics and the OCT system specification. These effects should be considered when interpreting DOCT images.

Biomedical Optics ExpressVol. 16(8)
Damietta University (EG), University of Tsukuba (JP), Indian Institute of Technology Delhi (IN)
Japan Society for the Promotion of Science, Japan Science and Technology Agency, Core Research for Evolutional Science and Technology
Openalex Percentile: Top 31%
Optical Coherence Tomography Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals — Atsuko Furukawa, Thitiya Seesan, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS