Assessment of the effect of scan body splinting on the trueness of digital impression in complete-arch implant-supported prosthesis: A comparative in vitro study

Aim: To assess whether splinting of scan bodies or not affects the trueness of a complete-arch digital implant impression by comparing it with the gold standard splinted open-top conventional technique. Materials and Methods: A mandibular resin model with four parallel digital implant analogues in the 36, 33, 43, and 46 tooth positions was used. On the model, three impression techniques were performed: conventional splinted implant level open tray impression (Group I), digital impression using an intraoral scanner with separate scan bodies (Group II), and digital impression using an intraoral scanner with splinted scan bodies (Group III). The trueness of the impressions was evaluated using surface matching software. Statistical analysis was done using repeated measures ANOVA, followed by Bonferroni post hoc test. Results: The results revealed that there is a significant difference between the trueness of the three techniques (p > 0.001), with the least deviation recorded in Group I (54.45±5.60 µm) and the highest deviation recorded in Group II (97.90±6.62 µm). Conclusion Splinting of the scan bodies causes significant improvement in the trueness of the complete-arch digital impression using an intraoral scanner.

Authors

Institutions

Publication Details

Journal
Ain Shams Dental Journal
Published
2025-03-01
DOI
https://doi.org/10.21608/asdj.2024.301792.1357
Citations
1
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of the effect of scan body splinting on the trueness of digital impression in complete-arch implant-supported prosthesis: A comparative in vitro study

Amany Mostafa Saad Farahat, Tarek Mohamed Al Sayed El Saaedi
1 citations
Ain Shams Dental Journal
Dental Implant Techniques and Outcomes
1.79
article

Assessment of the effect of scan body splinting on the trueness of digital impression in complete-arch implant-supported prosthesis: A comparative in vitro study

Amany Mostafa Saad Farahat, Tarek Mohamed Al Sayed El Saaedi
article en
1 citations

Abstract

Aim: To assess whether splinting of scan bodies or not affects the trueness of a complete-arch digital implant impression by comparing it with the gold standard splinted open-top conventional technique. Materials and Methods: A mandibular resin model with four parallel digital implant analogues in the 36, 33, 43, and 46 tooth positions was used. On the model, three impression techniques were performed: conventional splinted implant level open tray impression (Group I), digital impression using an intraoral scanner with separate scan bodies (Group II), and digital impression using an intraoral scanner with splinted scan bodies (Group III). The trueness of the impressions was evaluated using surface matching software. Statistical analysis was done using repeated measures ANOVA, followed by Bonferroni post hoc test. Results: The results revealed that there is a significant difference between the trueness of the three techniques (p > 0.001), with the least deviation recorded in Group I (54.45±5.60 µm) and the highest deviation recorded in Group II (97.90±6.62 µm). Conclusion Splinting of the scan bodies causes significant improvement in the trueness of the complete-arch digital impression using an intraoral scanner.

Ain Shams Dental JournalVol. 37(1)
Ain Shams University (EG)
Openalex Percentile: Top 16%
Dental Implant Techniques and Outcomes
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of the effect of scan body splinting on the trueness of digital impression in complete-arch implant-supported prosthesis: A comparative in vitro study — Amany Mostafa Saad Farahat, Tarek Mohamed Al Sayed El Saaedi · Ain Shams Dental Journal (2025) | TGRS Research Map | TGRS