Does level of breast support differentially affect exertional symptoms and respiratory system responses in large- and small-breasted women during treadmill exercise?
We assessed how different levels of breast support affected exertional symptoms and respiratory responses in small- and large-breasted females during treadmill exercise. Twenty recreationally-active females (mean ± SD age: 22 ± 2 years) were divided into small (SBV: 322±77 mL) and large breast volume (LBV: 580±88 mL; <i>p</i> < 0.001, <i>g</i> = 2.98) groups. Participants completed three 5 min bouts of treadmill exercise at 30%, 60%, and 90% of individual peak power output (PPO)-corresponding to walking, low-intensity running, and high-intensity running-wearing either a high-support or low-support sports bra (randomized). Measurements included cardiorespiratory variables, operating lung volumes, inspiratory muscle electromyographic, respiratory muscle pressures, breast acceleration, and exertional symptoms (breathlessness, chest tightness due to bra). High- versus low-support sports bras reduced mean breast acceleration (<i>p <</i> 0.001, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msubsup><mml:mi>η</mml:mi> <mml:mi>p</mml:mi> <mml:mn>2</mml:mn></mml:msubsup> </mml:math> =0.55), but evoked higher ratings of chest tightness (<i>p =</i> 0.040, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msubsup><mml:mi>η</mml:mi> <mml:mi>p</mml:mi> <mml:mn>2</mml:mn></mml:msubsup> </mml:math> =0.16) in LBV participants at low- and high-intensity running (<i>g</i> = 1.09 and <i>g</i> = 0.99, respectively). Although breathlessness was not significantly different by bra or breast volume (all <i>p</i> > 0.05), LBV participants consistently reported breathlessness intensity and unpleasantness ≥ 1 Borg unit (BU) higher than SBV participants during low- and high-intensity running (breathlessness intensity: ∼5 vs. ∼3 BU at 60% PPO; ∼9 vs. ∼7 BU at 90% PPO; breathlessness unpleasantness: ∼4 vs. ∼2 BU at 60% PPO, ∼8 vs. ∼6 BU at 90% PPO). There were no differences in cardiorespiratory variables, inspiratory muscle activity, operating lung volumes between breast volume groups or sports bras (all <i>p</i> > 0.05). We emphasize the importance of addressing subjective discomfort, including chest tightness and breathlessness, when developing effective breast support for weight-bearing exercise, especially for larger-breasted individuals.
Authors
- Camilla R. Illidi (ORCID: https://orcid.org/0000-0002-4724-8105)
- Dennis Jensen
Institutions
- McGill University Health Centre (CA)
- McGill University (CA)
Publication Details
- Journal
- Applied Physiology Nutrition and Metabolism
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1139/apnm-2025-0043
- Primary Topic
- Exercise and Physiological Responses
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Mitacs