Feasibility study on using low dose CT for adaptive proton therapy

In adaptive proton therapy, imaging is imperative for daily patient setup, monitoring anatomical changes, dose prediction, and replanning. However, utilizing cone-beam computed tomography (CBCT) is limited by artifacts and inaccurate Hounsfield units (HUs). Although, in-room CT resolves these limitations, its accumulated imaging dose across multiple fractions is concerning for secondary radiation-induced malignancies, particularly when it comes to pediatric patients. This work comprehensively investigated the feasibility of using low dose CT images for online proton therapy adaptation. Two quality assurance and three anatomical phantoms were scanned using 18 different CT scan techniques. 10 proton therapy patients were included in this study. Patients were imaged daily using different techniques: normal clinical dose (conventional) CT scan and 2 low dose CT scans. The Signal-to-noise ratio (SNR) of the CT images with 3 imaging dose levels were investigated. Treatment plans were generated to study dosimetric impact of reduced imaging dose. With decreasing imaging dose, SNR was reduced in all cases. Dose calculation on the CTs showed minor variation of dose distributions in patient and phantom scans. Neither the target coverage nor organs-at-risk (OAR) sparing showed clinically considerable differences between conventional, low, and ultra-low dose CT scans. This study showed the feasibility of using low dose CT scans for replanning in adaptive proton therapy. Optimized CT protocols with low imaging dose should be determined based on each institution's practice and treatment sites.

Authors

Institutions

Publication Details

Journal
Medical dosimetry
Published
2025-01-01
DOI
https://doi.org/10.1016/j.meddos.2025.05.001
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility study on using low dose CT for adaptive proton therapy

Baozhou Sun, Arash Darafsheh, Yao Hao, Tianyu Zhao et al.
Medical dosimetry
Radiation Therapy and Dosimetry
article

Feasibility study on using low dose CT for adaptive proton therapy

Baozhou Sun, Arash Darafsheh, Yao Hao, Tianyu Zhao, Geoffrey D. Hugo, Tong Zhu, Tiezhi Zhang, Stephanie M. Perkins, Sydney Shindler
article en

Abstract

In adaptive proton therapy, imaging is imperative for daily patient setup, monitoring anatomical changes, dose prediction, and replanning. However, utilizing cone-beam computed tomography (CBCT) is limited by artifacts and inaccurate Hounsfield units (HUs). Although, in-room CT resolves these limitations, its accumulated imaging dose across multiple fractions is concerning for secondary radiation-induced malignancies, particularly when it comes to pediatric patients. This work comprehensively investigated the feasibility of using low dose CT images for online proton therapy adaptation. Two quality assurance and three anatomical phantoms were scanned using 18 different CT scan techniques. 10 proton therapy patients were included in this study. Patients were imaged daily using different techniques: normal clinical dose (conventional) CT scan and 2 low dose CT scans. The Signal-to-noise ratio (SNR) of the CT images with 3 imaging dose levels were investigated. Treatment plans were generated to study dosimetric impact of reduced imaging dose. With decreasing imaging dose, SNR was reduced in all cases. Dose calculation on the CTs showed minor variation of dose distributions in patient and phantom scans. Neither the target coverage nor organs-at-risk (OAR) sparing showed clinically considerable differences between conventional, low, and ultra-low dose CT scans. This study showed the feasibility of using low dose CT scans for replanning in adaptive proton therapy. Optimized CT protocols with low imaging dose should be determined based on each institution's practice and treatment sites.

Medical dosimetryVol. 50(4)
Washington University in St. Louis (US)
Washington University School of Medicine in St. Louis
Openalex Percentile: Top 78%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.