A simple, sensitive, and green method for the determination of 5-fluorouracil exploiting luminol electrochemiluminescence

This study presents a simple, sensitive, and environmentally friendly analytical method based on luminol electrochemiluminescence (ECL) for the quantification of 5-fluorouracil. The approach relies on the suppression of the luminol/hydrogen peroxide ECL signal in the presence of the analyte using a screen-printed carbon electrode (SPE). The total solution volume containing luminol, hydrogen peroxide, and the drug was only 40 μL, ensuring significant reagent savings and minimal waste generation, which qualifies it as a green analytical method. Under optimized conditions, the ECL method displayed a wide linear response range from 0.3 to 10 000 nmol L<sup>-1</sup>. The proposed technique achieved a detection limit of 0.1 nmol L<sup>-1</sup> and was successfully applied for the determination of 5-fluorouracil in artificial urine and plasma samples, with recovery values ranging from 95.00% to 100.18% and 97.54% to 103.74%, respectively.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00825e
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simple, sensitive, and green method for the determination of 5-fluorouracil exploiting luminol electrochemiluminescence

Flávio Santos Damos, Dênio Emanuel Pires Souto, Saimon Moraes Silva, Rita de Cássia Silva Luz et al.
Analytical Methods
Analytical Chemistry and Sensors
article

A simple, sensitive, and green method for the determination of 5-fluorouracil exploiting luminol electrochemiluminescence

Flávio Santos Damos, Dênio Emanuel Pires Souto, Saimon Moraes Silva, Rita de Cássia Silva Luz, Barbara Rodrigues Demétrio
article en

Abstract

This study presents a simple, sensitive, and environmentally friendly analytical method based on luminol electrochemiluminescence (ECL) for the quantification of 5-fluorouracil. The approach relies on the suppression of the luminol/hydrogen peroxide ECL signal in the presence of the analyte using a screen-printed carbon electrode (SPE). The total solution volume containing luminol, hydrogen peroxide, and the drug was only 40 μL, ensuring significant reagent savings and minimal waste generation, which qualifies it as a green analytical method. Under optimized conditions, the ECL method displayed a wide linear response range from 0.3 to 10 000 nmol L<sup>-1</sup>. The proposed technique achieved a detection limit of 0.1 nmol L<sup>-1</sup> and was successfully applied for the determination of 5-fluorouracil in artificial urine and plasma samples, with recovery values ranging from 95.00% to 100.18% and 97.54% to 103.74%, respectively.

Analytical MethodsVol. 17(25)
La Trobe University (AU), Universidade Federal do Maranhão (BR), Universidade Federal do Paraná (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa e ao Desenvolvimento Científico e Tecnológico do Maranhão, Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Openalex Percentile: Top 83%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A simple, sensitive, and green method for the determination of 5-fluorouracil exploiting luminol electrochemiluminescence — Flávio Santos Damos, Dênio Emanuel Pires Souto, et al. · Analytical Methods (2025) | TGRS Research Map | TGRS