Innovative modified light bulb technique with custom offset curettes for treating precollapsed femoral head osteonecrosis

Osteonecrosis of the femoral head is a devastating disease that accounts for 10-15% of all hip arthroplasty cases in the USA, eventually leading to femoral head collapse and joint destruction. Even the current forms of treatment only slightly slow down the progression of the disease itself. This article describes a modified lightbulb technique, which perfects the method, the instrument, and the flap used in order to ensure hip musculature preservation and improved outcomes. With the direct anterior approach, there is no need to perform surgical dislocation, so the time of the surgery is reduced, as well as the risk of vascular injury. The necrotic bone can be precisely removed using custom-made offset curettes, and a bone graft substitute and autograft can be placed under C-arm guidance. This technique may be beneficial in treating early osteonecrosis of the femoral head by reducing operative time and reducing the risk of complications related to surgical dislocation.

Authors

Institutions

Publication Details

Journal
Journal of Hip Preservation Surgery
Published
2025-05-24
DOI
https://doi.org/10.1093/jhps/hnaf021
Primary Topic
Bone and Joint Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative modified light bulb technique with custom offset curettes for treating precollapsed femoral head osteonecrosis

Elham Rahmanipour, Mohammad Ghorbani, Ali Parsa, Neda Mirzaei et al.
Journal of Hip Preservation Surgery
Bone and Joint Diseases
article

Innovative modified light bulb technique with custom offset curettes for treating precollapsed femoral head osteonecrosis

Elham Rahmanipour, Mohammad Ghorbani, Ali Parsa, Neda Mirzaei, Morteza Behjat
article en

Abstract

Osteonecrosis of the femoral head is a devastating disease that accounts for 10-15% of all hip arthroplasty cases in the USA, eventually leading to femoral head collapse and joint destruction. Even the current forms of treatment only slightly slow down the progression of the disease itself. This article describes a modified lightbulb technique, which perfects the method, the instrument, and the flap used in order to ensure hip musculature preservation and improved outcomes. With the direct anterior approach, there is no need to perform surgical dislocation, so the time of the surgery is reduced, as well as the risk of vascular injury. The necrotic bone can be precisely removed using custom-made offset curettes, and a bone graft substitute and autograft can be placed under C-arm guidance. This technique may be beneficial in treating early osteonecrosis of the femoral head by reducing operative time and reducing the risk of complications related to surgical dislocation.

Journal of Hip Preservation SurgeryVol. 13(1)
Iran University of Medical Sciences (IR), Mashhad University of Medical Sciences (IR), Rasool Akram Hospital (IR), American Hip Institute (US)
Openalex Percentile: Top 83%
Bone and Joint Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Innovative modified light bulb technique with custom offset curettes for treating precollapsed femoral head osteonecrosis — Elham Rahmanipour, Mohammad Ghorbani, et al. · Journal of Hip Preservation Surgery (2025) | TGRS Research Map | TGRS