Three Spodumene Reference Materials for Oxygen Isotope Measurement by Ion Microprobe

This study reports on the development of three spodumene reference materials referred to as Curtin University (CU) Tri‐1, Kun‐A‐1 and MG‐1 for calibrating the instrumental mass fractionation for oxygen isotope measurement by secondary ionisation mass spectrometry (SIMS). Millimetre‐sized fragments were prepared from gem‐quality spodumene crystals with chemical compositions close to the ideal spodumene end member (LiAlSi 2 O 6 ). From these fragments, six subsamples were extracted for laser fluorination isotope ratio mass spectrometry (LF‐IRMS) to determine the bulk oxygen isotope ratio of the three materials and confirm their homogeneity on the mg scale. The bulk δ 18 O (VSMOW) values are 11.29 ± 0.04‰, 9.12 ± 0.10‰ and 15.13 ± 0.08‰ (all 2SE, standard error of the mean) for materials Tri‐1, Kun‐A‐1 and MG‐1, respectively. A random selection of twenty or more fragments from each material was subjected to SIMS analysis. Repeatability of SIMS δ 18 O measurements was at most 0.24‰ (2 s ), indicating oxygen isotopic homogeneity on the ng scale. Crystal orientation effects potentially affecting SIMS analysis were systematically evaluated and found to be absent at levels equivalent to the repeatability of the method. Applications of the new materials lie mainly in furthering research on pegmatite formation and tracing of raw materials by providing the means for accurate, in situ oxygen isotope measurement in spodumene.

Authors

Institutions

Publication Details

Journal
Geostandards and Geoanalytical Research
Published
2025-06-11
DOI
https://doi.org/10.1111/ggr.70003
Citations
3
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
2.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three Spodumene Reference Materials for Oxygen Isotope Measurement by Ion Microprobe

Zakaria Quadir, Johannes Chischi, Hans C. Oskierski, Axel Karl Schmitt et al.
3 citations
Geostandards and Geoanalytical Research
Analytical chemistry methods development
2.26
article

Three Spodumene Reference Materials for Oxygen Isotope Measurement by Ion Microprobe

Zakaria Quadir, Johannes Chischi, Hans C. Oskierski, Axel Karl Schmitt, Benita Putlitz, Martin Wells, Kai Rankenburg, A. T. Hertwig
article en
3 citations

Abstract

This study reports on the development of three spodumene reference materials referred to as Curtin University (CU) Tri‐1, Kun‐A‐1 and MG‐1 for calibrating the instrumental mass fractionation for oxygen isotope measurement by secondary ionisation mass spectrometry (SIMS). Millimetre‐sized fragments were prepared from gem‐quality spodumene crystals with chemical compositions close to the ideal spodumene end member (LiAlSi 2 O 6 ). From these fragments, six subsamples were extracted for laser fluorination isotope ratio mass spectrometry (LF‐IRMS) to determine the bulk oxygen isotope ratio of the three materials and confirm their homogeneity on the mg scale. The bulk δ 18 O (VSMOW) values are 11.29 ± 0.04‰, 9.12 ± 0.10‰ and 15.13 ± 0.08‰ (all 2SE, standard error of the mean) for materials Tri‐1, Kun‐A‐1 and MG‐1, respectively. A random selection of twenty or more fragments from each material was subjected to SIMS analysis. Repeatability of SIMS δ 18 O measurements was at most 0.24‰ (2 s ), indicating oxygen isotopic homogeneity on the ng scale. Crystal orientation effects potentially affecting SIMS analysis were systematically evaluated and found to be absent at levels equivalent to the repeatability of the method. Applications of the new materials lie mainly in furthering research on pegmatite formation and tracing of raw materials by providing the means for accurate, in situ oxygen isotope measurement in spodumene.

Geostandards and Geoanalytical ResearchVol. 49(4)
Murdoch University (AU), Curtin University (AU), University of Lausanne (CH)
Australian Government, Curtin University of Technology, Murdoch University, Technische Universität Bergakademie Freiberg
Openalex Percentile: Top 13%
Analytical chemistry methods development
2.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.