Transient Stability Analysis of Islanded MV Microgrid Under Variable Load and Fault Events

The paper analyses the Electromagnetic Transient (EMT) stability analysis of a modified Medium Voltage (MV). This Microgrid (MG) comprises a Diesel Generator (DG) and a Photovoltaic (PV) source under balanced load conditions. The system model was operated in a stable grid-connected mode with only DG's, but the authors proposed a new system with DG and PV in an islanded operation scenario. Islanded MG must operate in a stable mode where controllers can take prompt action in the fault event and make the system more reliable. In this regard, the droop control and PI control manage DG's active power and PV system's power operation, respectively. The Western Electricity Coordination Council (WECC) plant control is utilised as the benchmark model with PV only for a large-scale PV plant model. The control parameters are optimised for both machines to improve the system's dynamic response. The effectiveness and robustness of the MV islanded system are examined under different operating conditions through extensive simulation studies in the DigSILENT PowerFactory software.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/i-coste63786.2024.11024565
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Stability Analysis of Islanded MV Microgrid Under Variable Load and Fault Events

Ali Arefi, Amirmehdi Yazdani, Muhammad Waqas
Islanding Detection in Power Systems
article

Transient Stability Analysis of Islanded MV Microgrid Under Variable Load and Fault Events

Ali Arefi, Amirmehdi Yazdani, Muhammad Waqas
article en

Abstract

The paper analyses the Electromagnetic Transient (EMT) stability analysis of a modified Medium Voltage (MV). This Microgrid (MG) comprises a Diesel Generator (DG) and a Photovoltaic (PV) source under balanced load conditions. The system model was operated in a stable grid-connected mode with only DG's, but the authors proposed a new system with DG and PV in an islanded operation scenario. Islanded MG must operate in a stable mode where controllers can take prompt action in the fault event and make the system more reliable. In this regard, the droop control and PI control manage DG's active power and PV system's power operation, respectively. The Western Electricity Coordination Council (WECC) plant control is utilised as the benchmark model with PV only for a large-scale PV plant model. The control parameters are optimised for both machines to improve the system's dynamic response. The effectiveness and robustness of the MV islanded system are examined under different operating conditions through extensive simulation studies in the DigSILENT PowerFactory software.

Murdoch University (AU), Bahria University (PK)
Climate action
Openalex Percentile: Top 72%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.