Highly Sensitive Dual-Channel PCF Based SPR Biosensor for Multi-Analyte Detection with Fabrication Tolerance Analysis

This research introduces an exceptionally sensitive PCF-SPR sensor with multiple channels, designed for detecting multiple analytes simultaneously. Numerical simulations, performed through the finite element method (FEM), were used to evaluate the sensor’s performance. The proposed design incorporates two different plasmonic materials: $\mathrm{Ch}-1$ uses a combination of Gold (Au) and Tantalum Pentoxide (Ta<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</inf>), whereas $\mathrm{Ch}-2$ relies solely on Gold (Au). Demonstrating exceptional sensitivity spanning refractive index (RI) changes from 1.33 to 1.38 and 1.33 to 1.41, it achieves maximum wavelength sensitivities of 83,000 $\mathrm{nm} /$ RIU for Ch-1 and $22,000 \mathrm{~nm} /$ RIU for Ch-2. Additionally, it exhibits remarkable maximum amplitude sensitivities of 1167.9 RIU $^{-1}$ and 909.1 RIU $^{-1}$ for Ch-1 and Ch-2, respectively, alongside a minimum sensor resolution of $1.2 \times 10^{-6}$ RIU. The sensor sets a new standard with a figure of merit (FOM) of $2371 \mathrm{RIU}^{-1}$, outperforming previously documented multichannel sensors. It addresses existing limitations by offering greater sensitivity, enhanced detection precision, easier fabrication, a higher FOM, and improved resolution. We anticipate that this sensor will be effectively utilized to detect a wide array of substances, including chemicals, organic and inorganic compounds, medical diagnostics, food safety, and biochemical research.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/icece64886.2024.11024947
Primary Topic
Plasmonic and Surface Plasmon Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive Dual-Channel PCF Based SPR Biosensor for Multi-Analyte Detection with Fabrication Tolerance Analysis

Jobaida Akhtar, Md. Ibrahim Khalil, Faisal Ahmed Chowdhury, Mohammad Istiaque Reja et al.
Plasmonic and Surface Plasmon Research
article

Highly Sensitive Dual-Channel PCF Based SPR Biosensor for Multi-Analyte Detection with Fabrication Tolerance Analysis

Jobaida Akhtar, Md. Ibrahim Khalil, Faisal Ahmed Chowdhury, Mohammad Istiaque Reja, Mohammad Rezaul Karim, Md. Abdullah
article en

Abstract

This research introduces an exceptionally sensitive PCF-SPR sensor with multiple channels, designed for detecting multiple analytes simultaneously. Numerical simulations, performed through the finite element method (FEM), were used to evaluate the sensor’s performance. The proposed design incorporates two different plasmonic materials: $\mathrm{Ch}-1$ uses a combination of Gold (Au) and Tantalum Pentoxide (Ta<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</inf>), whereas $\mathrm{Ch}-2$ relies solely on Gold (Au). Demonstrating exceptional sensitivity spanning refractive index (RI) changes from 1.33 to 1.38 and 1.33 to 1.41, it achieves maximum wavelength sensitivities of 83,000 $\mathrm{nm} /$ RIU for Ch-1 and $22,000 \mathrm{~nm} /$ RIU for Ch-2. Additionally, it exhibits remarkable maximum amplitude sensitivities of 1167.9 RIU $^{-1}$ and 909.1 RIU $^{-1}$ for Ch-1 and Ch-2, respectively, alongside a minimum sensor resolution of $1.2 \times 10^{-6}$ RIU. The sensor sets a new standard with a figure of merit (FOM) of $2371 \mathrm{RIU}^{-1}$, outperforming previously documented multichannel sensors. It addresses existing limitations by offering greater sensitivity, enhanced detection precision, easier fabrication, a higher FOM, and improved resolution. We anticipate that this sensor will be effectively utilized to detect a wide array of substances, including chemicals, organic and inorganic compounds, medical diagnostics, food safety, and biochemical research.

Chittagong University of Engineering & Technology (BD), Daffodil International University (BD)
Affordable and clean energy
Openalex Percentile: Top 74%
Plasmonic and Surface Plasmon Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.