Grid Impedance Estimation for Hybrid GFL and GFM Systems

The hybrid systems, including a grid-following inverter(GFL) and a grid-forming inverter(GFM), are extensively utilized in distributed generation. Grid impedance is also critical to controller design and plays an important metric in analyzing system stability. Most impedance estimation methods consider the case of a single inverter, and the methods for multiple inverters ignore the effect of GFM. Meanwhile, they are based on steady-state cases and do not consider dynamic processes in which unstable cases could happen. This paper analyzes the impedance model of the hybrid system and constructs a mathematical model in the α-β frame, capturing the system dynamics. Based on this model, a non-intrusive grid impedance estimation method is proposed using the least squares (RLS) algorithm. The method does not require perturbation injection and can work during system dynamics or in unstable cases, which is instructive for the control and stability analysis of inverters. Simulation results verify the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Published
2025-03-28
DOI
https://doi.org/10.1109/aeees64634.2025.11019996
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid Impedance Estimation for Hybrid GFL and GFM Systems

Hankang Tian, Jiaqi Yu, Jingrong Yu, Wenxuan Yao et al.
Microgrid Control and Optimization
article

Grid Impedance Estimation for Hybrid GFL and GFM Systems

Hankang Tian, Jiaqi Yu, Jingrong Yu, Wenxuan Yao, Chen Peng
article en

Abstract

The hybrid systems, including a grid-following inverter(GFL) and a grid-forming inverter(GFM), are extensively utilized in distributed generation. Grid impedance is also critical to controller design and plays an important metric in analyzing system stability. Most impedance estimation methods consider the case of a single inverter, and the methods for multiple inverters ignore the effect of GFM. Meanwhile, they are based on steady-state cases and do not consider dynamic processes in which unstable cases could happen. This paper analyzes the impedance model of the hybrid system and constructs a mathematical model in the α-β frame, capturing the system dynamics. Based on this model, a non-intrusive grid impedance estimation method is proposed using the least squares (RLS) algorithm. The method does not require perturbation injection and can work during system dynamics or in unstable cases, which is instructive for the control and stability analysis of inverters. Simulation results verify the effectiveness of the proposed method.

Central South University (CN), Hunan University (CN), Changsha University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province
Affordable and clean energy
Openalex Percentile: Top 85%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.