Research on Insulation Performance of Low Frequency Potential Transformer

With the accelerated implementation of the ‘dual-carbon’ strategic objectives, the exponential growth of offshore wind power installations has imposed elevated technical demands on flexible low-frequency AC transmission systems. As a key equipment in low-frequency transmission system, the insulation performance of potential transformer (PT) directly affects the reliability and system safety of electric energy metering. However, there is still a lack of research on the insulation characteristics of PT under low frequency conditions. In this paper, 220 kV low-frequency electromagnetic PT is taken as the research object. Through theoretical modeling and finite element simulation, the influence of inter-turn insulation thickness, winding outer insulation layer design and shell distance on its insulation performance is systematically analyzed. The research results provide an important reference for the optimal design of low frequency PT and the reliable operation of offshore wind power flexible low frequency transmission system.

Authors

Institutions

Publication Details

Published
2025-03-28
DOI
https://doi.org/10.1109/aeees64634.2025.11019556
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Insulation Performance of Low Frequency Potential Transformer

Xinyu Sun, Qiyu Jiao, Le Han, Jiayi Zhang et al.
3 links
High voltage insulation and dielectric phenomena
article

Research on Insulation Performance of Low Frequency Potential Transformer

Xinyu Sun, Qiyu Jiao, Le Han, Jiayi Zhang, Changqing Ma, Zihao Xu
article en

Abstract

With the accelerated implementation of the ‘dual-carbon’ strategic objectives, the exponential growth of offshore wind power installations has imposed elevated technical demands on flexible low-frequency AC transmission systems. As a key equipment in low-frequency transmission system, the insulation performance of potential transformer (PT) directly affects the reliability and system safety of electric energy metering. However, there is still a lack of research on the insulation characteristics of PT under low frequency conditions. In this paper, 220 kV low-frequency electromagnetic PT is taken as the research object. Through theoretical modeling and finite element simulation, the influence of inter-turn insulation thickness, winding outer insulation layer design and shell distance on its insulation performance is systematically analyzed. The research results provide an important reference for the optimal design of low frequency PT and the reliable operation of offshore wind power flexible low frequency transmission system.

Hohai University (CN), Nanjing University of Information Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 91%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Insulation Performance of Low Frequency Potential Transformer — Xinyu Sun, Qiyu Jiao, et al. · (2025) | TGRS Research Map | TGRS