Research and Application of Multi-Point Feeder Automation For Overhead Lines In Intelligent Distribution

At the present time, Distribution automation FA deployed at the outgoing intervals of the substation, In the event of a fault on the line, the fault is isolated by tripping the outgoing switch at the substation,But, Easily expanding the scope of fault when complex lines are involved, At the same time, the substation outgoing interval data can not be effectively direct mining led to distribution network,so, FA can not be put into normal operation, further resulting in an increase in the number of power outage users, In order to address the above issues, Deployment of FA on smart 5G switches with three-remote function for 10kV lines in distribution networks, And redesign the launch strategy of the FA, The occurrence of 5G switch tripping necessitates the implementation of protective measures on the line as the FA start condition. When faults accurt, Isolation of faults in close proximity by the 5G switch on the line, Reducing the scope of power outages. The program has been put into use in one of the Chinese districts with remarkable results

Authors

Publication Details

Published
2025-03-28
DOI
https://doi.org/10.1109/aeees64634.2025.11019079
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and Application of Multi-Point Feeder Automation For Overhead Lines In Intelligent Distribution

Yi Zhao, Zhenhua Huang, G. Chen, Shengwei Wang et al.
Power Systems and Technologies
article

Research and Application of Multi-Point Feeder Automation For Overhead Lines In Intelligent Distribution

Yi Zhao, Zhenhua Huang, G. Chen, Shengwei Wang, Wei Gu
article en

Abstract

At the present time, Distribution automation FA deployed at the outgoing intervals of the substation, In the event of a fault on the line, the fault is isolated by tripping the outgoing switch at the substation,But, Easily expanding the scope of fault when complex lines are involved, At the same time, the substation outgoing interval data can not be effectively direct mining led to distribution network,so, FA can not be put into normal operation, further resulting in an increase in the number of power outage users, In order to address the above issues, Deployment of FA on smart 5G switches with three-remote function for 10kV lines in distribution networks, And redesign the launch strategy of the FA, The occurrence of 5G switch tripping necessitates the implementation of protective measures on the line as the FA start condition. When faults accurt, Isolation of faults in close proximity by the 5G switch on the line, Reducing the scope of power outages. The program has been put into use in one of the Chinese districts with remarkable results

Openalex Percentile: Top 89%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research and Application of Multi-Point Feeder Automation For Overhead Lines In Intelligent Distribution — Yi Zhao, Zhenhua Huang, et al. · (2025) | TGRS Research Map | TGRS