Improved Multi-Carrier Modulation Strategy Suitable for Cascade H-Bridge Photovoltaic Inverters

Grid-connected photovoltaic systems often prefer transformer-less inverters because of their high efficiency, low cost, and lightweight design. However, without electrical isolation, leakage currents may flow through the system, resulting in increased losses, electromagnetic interference, harmonic distortion, and potential safety hazards. This study addresses this issue. Firstly, the common mode equivalent model of single-phase five-level cascaded H-bridge PV grid-connected inverter was established and the main factors affecting the leakage current were analyzed. Subsequent suppression of leakage current is achieved by reducing the rate of change of the sum of parasitic capacitor voltages during the switching state, and the strategy is simple to implement. Finally, the effectiveness of the proposed modulation strategy is verified by simulation analysis.

Authors

Institutions

Publication Details

Published
2025-03-28
DOI
https://doi.org/10.1109/aeees64634.2025.11019475
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Multi-Carrier Modulation Strategy Suitable for Cascade H-Bridge Photovoltaic Inverters

Bowen Liu, Lin Chai, Zhangheng Peng
Multilevel Inverters and Converters
article

Improved Multi-Carrier Modulation Strategy Suitable for Cascade H-Bridge Photovoltaic Inverters

Bowen Liu, Lin Chai, Zhangheng Peng
article en

Abstract

Grid-connected photovoltaic systems often prefer transformer-less inverters because of their high efficiency, low cost, and lightweight design. However, without electrical isolation, leakage currents may flow through the system, resulting in increased losses, electromagnetic interference, harmonic distortion, and potential safety hazards. This study addresses this issue. Firstly, the common mode equivalent model of single-phase five-level cascaded H-bridge PV grid-connected inverter was established and the main factors affecting the leakage current were analyzed. Subsequent suppression of leakage current is achieved by reducing the rate of change of the sum of parasitic capacitor voltages during the switching state, and the strategy is simple to implement. Finally, the effectiveness of the proposed modulation strategy is verified by simulation analysis.

Wuhan University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 89%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.