<b>Purpose:</b> The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. <b>Methods:</b> In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. <b>Results:</b> 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (<i>p</i> = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. <b>Conclusions:</b> The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.

Authors

Institutions

Publication Details

Journal
Journal of Ophthalmology
Published
2025-01-01
DOI
https://doi.org/10.1155/joph/6959314
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation

Álvarez-Rementería Capelo L, Jesús Beltrán-Murcia, Vanesa Blázquez
Journal of Ophthalmology
Corneal surgery and disorders
article

Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation

Álvarez-Rementería Capelo L, Jesús Beltrán-Murcia, Vanesa Blázquez
article en

Abstract

<b>Purpose:</b> The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. <b>Methods:</b> In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. <b>Results:</b> 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (<i>p</i> = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. <b>Conclusions:</b> The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.

Journal of OphthalmologyVol. 2025(1)
Universidad Complutense de Madrid (ES), Clínica Rementería (ES)
Openalex Percentile: Top 80%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation — Álvarez-Rementería Capelo L, Jesús Beltrán-Murcia, et al. · Journal of Ophthalmology (2025) | TGRS Research Map | TGRS