Establishment of ABEI-based direct chemiluminescence immunoassays for PIC, TAT, tPAIC, and TM and their preliminary evaluation in thrombotic diseases

Thromboembolism is a leading cause of mortality worldwide. Screening and diagnosis are essential for the prevention and control of thrombotic diseases. This study evaluated four newly developed chemiluminescence assays for the detection of α2-plasmininhibitor-plasmin complex (PIC), thrombin-antithrombin III complex (TAT), tissue plasminogen activator-plasminogen activator inhibitor complex (tPAIC) and thrombomodulin (TM) based on an <i>N</i>-(4-aminobutyl)-<i>N</i>-ethylisoluminol (ABEI)-hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) system. Results demonstrated that the proposed MAGLUMI PIC, TAT, tPAIC and TM tests exhibited good analytical performance and were in good concordance with the SYSMEX system. Compared with the controls, patients with thrombotic diseases exhibited significantly elevated levels of TAT, PIC, TM, and tPAIC in disseminated intravascular coagulation (DIC) and elevated levels of TAT, PIC, and tPAIC in ischemic stroke (IS). Logistic regression analysis and receiver operating characteristic (ROC) curve analysis showed that combined PIC and tPAIC contributed to the best area under the curve (AUC) value of 0.915 (95% confidence interval (CI): 0.859-0.959) for DIC diagnosis. The diagnostic system formed using TAT, PIC, and tPAIC could be used for IS diagnosis with an AUC value of 0.839 (95% CI: 0.762-0.899). Our study demonstrates the good performance of MAGLUMI TAT, PIC, tPAIC and TM CLIA tests, suggesting their potential for thrombotic disease diagnosis, and the combination of these thrombosis markers could provide an enhancement in diagnostic efficacy.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00537j
Citations
2
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of ABEI-based direct chemiluminescence immunoassays for PIC, TAT, tPAIC, and TM and their preliminary evaluation in thrombotic diseases

Ke Huang, Mingzhe Weng, Xiaolong Gan, Jinqiu Fu et al.
2 citations
Analytical Methods
Advanced Biosensing Techniques and Applications
1.61
article

Establishment of ABEI-based direct chemiluminescence immunoassays for PIC, TAT, tPAIC, and TM and their preliminary evaluation in thrombotic diseases

Ke Huang, Mingzhe Weng, Xiaolong Gan, Jinqiu Fu, Hong Sun, Yun Zhang, Xue Li, Kun Liu, Jiayi Zhang, Lin Qiu, Hua Pei, Zhonggang Fang
article en
2 citations

Abstract

Thromboembolism is a leading cause of mortality worldwide. Screening and diagnosis are essential for the prevention and control of thrombotic diseases. This study evaluated four newly developed chemiluminescence assays for the detection of α2-plasmininhibitor-plasmin complex (PIC), thrombin-antithrombin III complex (TAT), tissue plasminogen activator-plasminogen activator inhibitor complex (tPAIC) and thrombomodulin (TM) based on an <i>N</i>-(4-aminobutyl)-<i>N</i>-ethylisoluminol (ABEI)-hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) system. Results demonstrated that the proposed MAGLUMI PIC, TAT, tPAIC and TM tests exhibited good analytical performance and were in good concordance with the SYSMEX system. Compared with the controls, patients with thrombotic diseases exhibited significantly elevated levels of TAT, PIC, TM, and tPAIC in disseminated intravascular coagulation (DIC) and elevated levels of TAT, PIC, and tPAIC in ischemic stroke (IS). Logistic regression analysis and receiver operating characteristic (ROC) curve analysis showed that combined PIC and tPAIC contributed to the best area under the curve (AUC) value of 0.915 (95% confidence interval (CI): 0.859-0.959) for DIC diagnosis. The diagnostic system formed using TAT, PIC, and tPAIC could be used for IS diagnosis with an AUC value of 0.839 (95% CI: 0.762-0.899). Our study demonstrates the good performance of MAGLUMI TAT, PIC, tPAIC and TM CLIA tests, suggesting their potential for thrombotic disease diagnosis, and the combination of these thrombosis markers could provide an enhancement in diagnostic efficacy.

Analytical MethodsVol. 17(26)
Hainan Medical University (CN)
Openalex Percentile: Top 17%
Advanced Biosensing Techniques and Applications
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.