Handheld confocal laser endomicroscopy using an asymmetric electrothermal MEMS micromirror for in vivo distortion-free imaging

Electrothermal micromirrors are suitable for miniaturization of confocal laser endomicroscopic (CLE) probes for in vivo imaging of internal organs due to their large linear scan range at low actuation voltages, but high-speed imaging requires resonant scanning under which those electrothermal micromirrors exhibit strong cross-axis coupling that leads to serious image reconstruction distortions. This paper presents a custom-built CLE probe that utilizes a two-axis asymmetric electrothermal MEMS mirror to achieve distortion-free in vivo imaging. The MEMS mirror with a size of 2mm × 2 mm is integrated into the CLE probe with a diameter of 8.6 mm. Fluorescence confocal images of <i>in vivo</i> and <i>ex vivo</i> animal tissues have been successfully acquired. Experiments show that the CLE probe achieved a lateral resolution of 1.5 μm and a field of view of 580 μm × 700 μm with a voltage as low as 4 V. This CLE probe supports both linear and resonant scanning modes, with a maximum imaging rate of 10 fps, demonstrating the probe's potential for point-of-care histological diagnosis.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-06-11
DOI
https://doi.org/10.1364/oe.565051
Citations
2
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Handheld confocal laser endomicroscopy using an asymmetric electrothermal MEMS micromirror for in vivo distortion-free imaging

Wenlong Jiao, Huikai Xie, Teng Pan, Qian Chen et al.
2 citations
Optics Express
Photoacoustic and Ultrasonic Imaging
1.35
article

Handheld confocal laser endomicroscopy using an asymmetric electrothermal MEMS micromirror for in vivo distortion-free imaging

Wenlong Jiao, Huikai Xie, Teng Pan, Qian Chen, Ruixue Li, Tingxiang Qi, Yue Tang, Jia Pu, Xiaodan Mao
article en
2 citations

Abstract

Electrothermal micromirrors are suitable for miniaturization of confocal laser endomicroscopic (CLE) probes for in vivo imaging of internal organs due to their large linear scan range at low actuation voltages, but high-speed imaging requires resonant scanning under which those electrothermal micromirrors exhibit strong cross-axis coupling that leads to serious image reconstruction distortions. This paper presents a custom-built CLE probe that utilizes a two-axis asymmetric electrothermal MEMS mirror to achieve distortion-free in vivo imaging. The MEMS mirror with a size of 2mm × 2 mm is integrated into the CLE probe with a diameter of 8.6 mm. Fluorescence confocal images of <i>in vivo</i> and <i>ex vivo</i> animal tissues have been successfully acquired. Experiments show that the CLE probe achieved a lateral resolution of 1.5 μm and a field of view of 580 μm × 700 μm with a voltage as low as 4 V. This CLE probe supports both linear and resonant scanning modes, with a maximum imaging rate of 10 fps, demonstrating the probe's potential for point-of-care histological diagnosis.

Optics ExpressVol. 33(13)
Ministry of Education of the People's Republic of China (CN), Beijing Microelectronics Technology Institute (CN), Institute of Microelectronics (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Beijing Municipal Natural Science Foundation
Openalex Percentile: Top 19%
Photoacoustic and Ultrasonic Imaging
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.