NUMERICAL INVESTIGATION OF THE BEHAVIOR OF BOLTED STAINLESS-STEEL BEAM-TO-COLUMN JOINT

This study presents a numerical investigation into the moment-rotation behavior of bolted stainless-steel beam-to-column joints using Finite Element (FE) modeling in ABAQUS, validated against experimental data.A series of numerical models is developed to assess the influence of angle cleat thickness (ta), angle cleat leg length (L) parallel to the column flange, and column flange thickness (tc) on joint performance.The results demonstrate that increasing ta from 10 mm to 16 mm enhances the maximum moment capacity (Mu) by 18.0%, indicating a significant improvement in load resistance.Conversely, extending L from 80 mm to 140 mm reduces Mu by 16.1%, while increasing rotational capacity by 80.4%, highlighting improved deformation capacity before failure.Changes in tc exhibit a relatively minor effect, with a negligible influence on overall joint strength.These findings provide critical insights into the design and optimization of stainless steel connections, contributing to the development of more efficient and reliable structural applications.

Authors

Publication Details

Journal
International Journal of Geomate
Published
2025-06-11
DOI
https://doi.org/10.21660/2025.130.4923
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NUMERICAL INVESTIGATION OF THE BEHAVIOR OF BOLTED STAINLESS-STEEL BEAM-TO-COLUMN JOINT

Xuân Bàng Nguyễn
International Journal of Geomate
Structural Load-Bearing Analysis
article

NUMERICAL INVESTIGATION OF THE BEHAVIOR OF BOLTED STAINLESS-STEEL BEAM-TO-COLUMN JOINT

Xuân Bàng Nguyễn
article en

Abstract

This study presents a numerical investigation into the moment-rotation behavior of bolted stainless-steel beam-to-column joints using Finite Element (FE) modeling in ABAQUS, validated against experimental data.A series of numerical models is developed to assess the influence of angle cleat thickness (ta), angle cleat leg length (L) parallel to the column flange, and column flange thickness (tc) on joint performance.The results demonstrate that increasing ta from 10 mm to 16 mm enhances the maximum moment capacity (Mu) by 18.0%, indicating a significant improvement in load resistance.Conversely, extending L from 80 mm to 140 mm reduces Mu by 16.1%, while increasing rotational capacity by 80.4%, highlighting improved deformation capacity before failure.Changes in tc exhibit a relatively minor effect, with a negligible influence on overall joint strength.These findings provide critical insights into the design and optimization of stainless steel connections, contributing to the development of more efficient and reliable structural applications.

International Journal of GeomateVol. 28(130)
Sustainable cities and communities
Openalex Percentile: Top 86%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

NUMERICAL INVESTIGATION OF THE BEHAVIOR OF BOLTED STAINLESS-STEEL BEAM-TO-COLUMN JOINT — Xuân Bàng Nguyễn · International Journal of Geomate (2025) | TGRS Research Map | TGRS