Benchmarking TERS and TEPL probes: towards a reference sample for quantification of near-field enhancement factors in gap and non-gap modes
Benchmarking the near-field signal enhancement attained using plasmonic metal-coated atomic force microscopy (AFM) probes for tip-enhanced Raman spectroscopy (TERS) and tip-enhanced photoluminescence (TEPL) measurements is challenging given the absence of a suitable reference sample that is simple to prepare, easy to use and compatible with different instrument configurations. To this end, in this study, we have fabricated a flake of monolayer tungsten diselenide (1L-WSe<sub>2</sub>) stamped across the interface of gold and silver thin films on silicon dioxide and glass. We have demonstrated these samples to be effective for the facile determination of near-field Raman and photoluminescence contrast factors in both gap and non-gap mode, respectively. We show that the near-degenerate E12g + A<sub>1g</sub> and 2LA(M) peaks in the Raman spectra of WSe<sub>2</sub> enable quantification of Raman contrast factors, with a ∼1.6-fold increase in TERS signal enhancement in gap mode, relative to non-gap mode, observed for a typical probe. Similar differences in the photoluminescence contrast factors were observed comparing in-contact and out-of-contact signal intensity ratios from gap and non-gap mode TEPL measurements. Moreover, in developing a reference methodology we found that the line shape of the TEPL profile was dependent upon the magnitude of the signal enhancement, with a disproportionate increase in the longer wavelength shoulder of the emission observed in gap mode. As this contribution to the asymmetric line shape is tentatively assigned to a dark exciton, which possesses an out-of-plane transition dipole moment, our TEPL measurements indicate that the directionality of the near-field enhancement provides a further handle enabling quantification of probe performance. Using samples prepared on glass, and comparing results obtained from two different instruments, each with a different excitation laser wavelength and optical access, we demonstrate the universal applicability of our reference material for sensitivity benchmarking of metallised AFM probes in both gap and non-gap mode, suitable for both reflection and transmission geometries, and across the range of laser wavelengths typically used for TERS and TEPL.
Authors
- Peter H. Beton (ORCID: https://orcid.org/0000-0002-2120-8033)
- Kai Roßnagel (ORCID: https://orcid.org/0000-0001-5107-0090)
- Elizabeth J. Legge (ORCID: https://orcid.org/0000-0002-3432-4017)
- Michael W. George (ORCID: https://orcid.org/0000-0002-7844-1696)
- Christopher J. Mellor (ORCID: https://orcid.org/0000-0001-5987-7876)
- Graham A. Rance (ORCID: https://orcid.org/0000-0002-8325-1096)
- Jasbinder Chauhan
- Andrew J. Pollard (ORCID: https://orcid.org/0000-0002-6841-2592)
- James Kerfoot (ORCID: https://orcid.org/0000-0002-6041-4833)
- Amy Collins
Institutions
- National Physical Laboratory (GB)
- University of Nottingham (GB)
- Deutsches Elektronen-Synchrotron DESY (DE)
- Christian-Albrechts-Universität zu Kiel (DE)
Publication Details
- Journal
- The Analyst
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1039/d5an00456j
- Citations
- 1
- Primary Topic
- Near-Field Optical Microscopy
- Type
- article
- Field-Weighted Citation Impact
- 0.67
Funders
- Engineering and Physical Sciences Research Council
- National Physical Laboratory