Electrochemical Polymerization of Guaiacol in Organic Solvents and Analytical Performance of the Poly (Guaiacol) Modified Electrode Towards Phenol Antioxidants

The electrochemical polymerization of guaiacol was studied in different organic solvents. Significant electrode blocking was observed in dichloromethane. Microscopic studies verified the formation of a coherent deposit on the platinum electrode. In acetonitrile, the insulating deposit formation proceeded above 20 mM monomer concentration. The differences in layer formation performed in acetic acid or ethyl acetate only allowed us to make estimations in a narrow range of the composition of their binary solvent mixtures utilizing the shape of curves related to guaiacol electropolymerization. Guaiacol was therefore not reliable in solvent composition estimations within the entire range. Due to its apolar nature, a poly (guaiacol) modified platinum macroelectrode was assessed for analyses in solutions prepared with organic solvents. The analytical performance of the modified electrode was tested with butylhydroxyanisole and butylhydroxytoluene. Linear sweep voltammetry was applied under stirred conditions, and the noise of stirring diminished compared with the bare electrode, although lower sensitivity was noticed.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-06-11
DOI
https://doi.org/10.3390/chemosensors13060214
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Polymerization of Guaiacol in Organic Solvents and Analytical Performance of the Poly (Guaiacol) Modified Electrode Towards Phenol Antioxidants

László Kiss, Péter Szabó, Sándor Kunsági‐Máté
Chemosensors
Electrochemical sensors and biosensors
article

Electrochemical Polymerization of Guaiacol in Organic Solvents and Analytical Performance of the Poly (Guaiacol) Modified Electrode Towards Phenol Antioxidants

László Kiss, Péter Szabó, Sándor Kunsági‐Máté
article en

Abstract

The electrochemical polymerization of guaiacol was studied in different organic solvents. Significant electrode blocking was observed in dichloromethane. Microscopic studies verified the formation of a coherent deposit on the platinum electrode. In acetonitrile, the insulating deposit formation proceeded above 20 mM monomer concentration. The differences in layer formation performed in acetic acid or ethyl acetate only allowed us to make estimations in a narrow range of the composition of their binary solvent mixtures utilizing the shape of curves related to guaiacol electropolymerization. Guaiacol was therefore not reliable in solvent composition estimations within the entire range. Due to its apolar nature, a poly (guaiacol) modified platinum macroelectrode was assessed for analyses in solutions prepared with organic solvents. The analytical performance of the modified electrode was tested with butylhydroxyanisole and butylhydroxytoluene. Linear sweep voltammetry was applied under stirred conditions, and the noise of stirring diminished compared with the bare electrode, although lower sensitivity was noticed.

ChemosensorsVol. 13(6)
University of Pecs (HU)
Pécsi Tudományegyetem
Openalex Percentile: Top 89%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.