On the Method of Harmonic Balance for Lumped‐Element Transformer Models

ABSTRACT Incorporating the magnetic core material in a lumped‐element transformer model generally results in a nonlinear network with hysteresis. Such a network can be solved subsequently in the time domain using time‐stepping methods. The transient response reveals the inrush, whose decay time is generally enormous compared to the time constant of the excitation period (e.g., 20 ms for a voltage source with a frequency of 50 Hz). To directly obtain the steady‐state solution of the lumped‐element transformer model, the harmonic balance method is superior to such an analysis, because it is a frequency domain approach inherently yielding the steady‐state solution. The great advantage of harmonic balance is that it can handle nonlinearities by evaluating them in the time domain and using their spectral components in the frequency domain. This paper theoretically derives the harmonic balance algorithm and further solves a lumped‐element single‐phase transformer model based on a mutual and leakage flux approach utilizing Hopkinson 's law. The nonlinear network element is represented by an energy‐based dry friction‐like hysteresis model depicting the core material of the transformer. The hysteresis parameters are fitted to no‐load current measurements, and the no‐load case, the short‐circuit case, and a chosen load case are simulated and compared to measurements. The algorithm's efficiency in terms of iterations and computational time is demonstrated by simulating with several excitation frequencies and for several load cases and comparing it to a transient analysis revealing the transformer's inrush.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2025-06-11
DOI
https://doi.org/10.1002/cta.70012
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Method of Harmonic Balance for Lumped‐Element Transformer Models

Manfred Kaltenbacher, Peter Hamberger, Alexander Sauseng, Klaus Roppert et al.
International Journal of Circuit Theory and Applications
Magnetic Properties and Applications
article

On the Method of Harmonic Balance for Lumped‐Element Transformer Models

Manfred Kaltenbacher, Peter Hamberger, Alexander Sauseng, Klaus Roppert, Dennis Albert, Alice Reinbacher‐Köstinger
article en

Abstract

ABSTRACT Incorporating the magnetic core material in a lumped‐element transformer model generally results in a nonlinear network with hysteresis. Such a network can be solved subsequently in the time domain using time‐stepping methods. The transient response reveals the inrush, whose decay time is generally enormous compared to the time constant of the excitation period (e.g., 20 ms for a voltage source with a frequency of 50 Hz). To directly obtain the steady‐state solution of the lumped‐element transformer model, the harmonic balance method is superior to such an analysis, because it is a frequency domain approach inherently yielding the steady‐state solution. The great advantage of harmonic balance is that it can handle nonlinearities by evaluating them in the time domain and using their spectral components in the frequency domain. This paper theoretically derives the harmonic balance algorithm and further solves a lumped‐element single‐phase transformer model based on a mutual and leakage flux approach utilizing Hopkinson 's law. The nonlinear network element is represented by an energy‐based dry friction‐like hysteresis model depicting the core material of the transformer. The hysteresis parameters are fitted to no‐load current measurements, and the no‐load case, the short‐circuit case, and a chosen load case are simulated and compared to measurements. The algorithm's efficiency in terms of iterations and computational time is demonstrated by simulating with several excitation frequencies and for several load cases and comparing it to a transient analysis revealing the transformer's inrush.

International Journal of Circuit Theory and ApplicationsVol. 54(2)
Omron (Japan) (JP), Graz University of Technology (AT), Siemens (Austria) (AT)
TU Graz, Internationale Beziehungen und Mobilitätsprogramme, Deutsche Forschungsgemeinschaft, Austrian Science Fund, Technische Universität Darmstadt
Openalex Percentile: Top 92%
Magnetic Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.