High Diagnostic Performance of the Indicator Plaster Neuropad for the Detection of Established Diabetic Autonomic Neuropathy

Aim: The aim of this study was to evaluate the specificity, sensitivity and accuracy of the Indicator Plaster Neuropad in detecting established Diabetic Autonomic Neuropathy (DAN). Methods: We studied 180 patients with Diabetes Mellitus (DM, mean age 49.5 ± 16 years, 82 with DM type 1). All patients underwent the following Cardiovascular Reflex Tests (CARTs): R-R variation during deep breathing (Mean Circular Resultant (MCR) and standard deviation (SD)), Valsalva maneuver, R-R variability after a rapid change from lying to standing position and postural hypotension. The presence of DAN was established if ≥2 CARTs were abnormal. According to the result the patients were divided into two groups, one with DAN and one without DAN. Assessment with Neuropad was performed also in all patients. Results: Abnormal perspiration with Neuropad (uncompleted or no change in color) was detected in 94 patients. Established DAN was detected in 85 patients. The sensitivity, specificity and accuracy of Neuropad for the diagnosis of established DAN were 87.1%, 78.9% and 82.8%, respectively and area under the curve was 0.846 and 95% CI (0.787, 0.905). Conclusions: Neuropad has high sensitivity, specificity, and accuracy in detecting established DAN, as defined by ≥2 abnormal CARTs.

Authors

Institutions

Publication Details

Journal
Diabetology
Published
2025-06-11
DOI
https://doi.org/10.3390/diabetology6060055
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Diagnostic Performance of the Indicator Plaster Neuropad for the Detection of Established Diabetic Autonomic Neuropathy

Theocharis Koufakis, C. Savopoulos, Ioanna Zografou, Evangelia Kotzakioulafi et al.
Diabetology
Heart Rate Variability and Autonomic Control
article

High Diagnostic Performance of the Indicator Plaster Neuropad for the Detection of Established Diabetic Autonomic Neuropathy

Theocharis Koufakis, C. Savopoulos, Ioanna Zografou, Evangelia Kotzakioulafi, Triantafyllos Didangelos, Panagiotis Doukelis, Kοnstantinos Kantartzis, Zisis Kontoninas, Michael Doumas, Polykarpos Evripidou
article en

Abstract

Aim: The aim of this study was to evaluate the specificity, sensitivity and accuracy of the Indicator Plaster Neuropad in detecting established Diabetic Autonomic Neuropathy (DAN). Methods: We studied 180 patients with Diabetes Mellitus (DM, mean age 49.5 ± 16 years, 82 with DM type 1). All patients underwent the following Cardiovascular Reflex Tests (CARTs): R-R variation during deep breathing (Mean Circular Resultant (MCR) and standard deviation (SD)), Valsalva maneuver, R-R variability after a rapid change from lying to standing position and postural hypotension. The presence of DAN was established if ≥2 CARTs were abnormal. According to the result the patients were divided into two groups, one with DAN and one without DAN. Assessment with Neuropad was performed also in all patients. Results: Abnormal perspiration with Neuropad (uncompleted or no change in color) was detected in 94 patients. Established DAN was detected in 85 patients. The sensitivity, specificity and accuracy of Neuropad for the diagnosis of established DAN were 87.1%, 78.9% and 82.8%, respectively and area under the curve was 0.846 and 95% CI (0.787, 0.905). Conclusions: Neuropad has high sensitivity, specificity, and accuracy in detecting established DAN, as defined by ≥2 abnormal CARTs.

DiabetologyVol. 6(6)
Aristotle University of Thessaloniki (GR), AHEPA University Hospital (GR), Deutsches Diabetes-Zentrum e.V. (DE), German Center for Diabetes Research (DE), Heinrich Heine University Düsseldorf (DE), University of Tübingen (DE)
Openalex Percentile: Top 76%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.