POWER SYSTEM ANALYSIS OF AN INDUSTRIAL ELECTRICAL NETWORK

The Tamil Nadu Electricity and Light (TEAL) industry is supplied with 11 kV voltage from TANGEDCO, with a 2.5 MVA distribution transformer and two panels for energized loads. A load flow, short circuit, and motor starting study were conducted using the Electrical Transient Analyzer Program (ETAP) platform. The load flow study found that the voltage profile at all buses is within the limit. Short circuit analysis was conducted using symmetrical and unsymmetrical faults, indicating that the available circuit breaker rating is sufficient. The highest capacity motor was identified as a 30 HP motor, drawing a large starting current from the supply during startup. A static motor starting study was conducted using the Institute of Electrical and Electronics Engineers (IEEE) 399–1997, IEEE 3002.7–2018 standards to check voltage dip at buses during motor startup. The voltage at other buses was also within the limit. Overall, the industry's voltage profile and motor starting are within the required limits.

Authors

Publication Details

Journal
Journal of Emerging Technologies and Innovative Research
Published
2025-01-01
DOI
https://doi.org/10.56975/jetir.v12i6.564150
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

POWER SYSTEM ANALYSIS OF AN INDUSTRIAL ELECTRICAL NETWORK

E. Latha Mercy, Dhivya Haarinie B
Journal of Emerging Technologies and Innovative Research
Power Quality and Harmonics
article

POWER SYSTEM ANALYSIS OF AN INDUSTRIAL ELECTRICAL NETWORK

E. Latha Mercy, Dhivya Haarinie B
article en

Abstract

The Tamil Nadu Electricity and Light (TEAL) industry is supplied with 11 kV voltage from TANGEDCO, with a 2.5 MVA distribution transformer and two panels for energized loads. A load flow, short circuit, and motor starting study were conducted using the Electrical Transient Analyzer Program (ETAP) platform. The load flow study found that the voltage profile at all buses is within the limit. Short circuit analysis was conducted using symmetrical and unsymmetrical faults, indicating that the available circuit breaker rating is sufficient. The highest capacity motor was identified as a 30 HP motor, drawing a large starting current from the supply during startup. A static motor starting study was conducted using the Institute of Electrical and Electronics Engineers (IEEE) 399–1997, IEEE 3002.7–2018 standards to check voltage dip at buses during motor startup. The voltage at other buses was also within the limit. Overall, the industry's voltage profile and motor starting are within the required limits.

Journal of Emerging Technologies and Innovative ResearchVol. 12(6)
Affordable and clean energy
Openalex Percentile: Top 89%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

POWER SYSTEM ANALYSIS OF AN INDUSTRIAL ELECTRICAL NETWORK — E. Latha Mercy, Dhivya Haarinie B · Journal of Emerging Technologies and Innovative Research (2025) | TGRS Research Map | TGRS