1,2‐Dichloroethane in Indoor Air

ABSTRACT 1,2‐Dichloroethane is a manmade compound used in the production of vinyl chloride. Due to its toxicity, it generally has relatively low screening levels based on acceptable concentrations in indoor air, soil vapor, and groundwater. If a release of 1,2‐dichloroethane has occurred, the compound may be detected in the subsurface and could be a risk driver for vapor intrusion (VI). Based on studies presented in this paper, however, this compound has become more frequently detected in indoor air and is likely attributed to sources in the buildings being sampled. This paper summarizes current knowledge of indoor air background levels of 1,2‐dichloroethane and potential sources. Recent field data demonstrate that the typical indoor air concentrations for this compound are higher than those reported in the past and may be connected to a larger presence of internationally shipped materials in the current indoor environment than in previous decades. This is an important consideration when evaluating buildings for VI, as background indoor air concentrations of 1,2‐dichloroethane may confound the VI pathway assessment.

Authors

Publication Details

Journal
Remediation Journal
Published
2025-04-01
DOI
https://doi.org/10.1002/rem.70025
Citations
1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1,2‐Dichloroethane in Indoor Air

Bart Eklund, Gina Plantz, Catherine Regan
1 citations
Remediation Journal
Indoor Air Quality and Microbial Exposure
1.20
article

1,2‐Dichloroethane in Indoor Air

Bart Eklund, Gina Plantz, Catherine Regan
article en
1 citations

Abstract

ABSTRACT 1,2‐Dichloroethane is a manmade compound used in the production of vinyl chloride. Due to its toxicity, it generally has relatively low screening levels based on acceptable concentrations in indoor air, soil vapor, and groundwater. If a release of 1,2‐dichloroethane has occurred, the compound may be detected in the subsurface and could be a risk driver for vapor intrusion (VI). Based on studies presented in this paper, however, this compound has become more frequently detected in indoor air and is likely attributed to sources in the buildings being sampled. This paper summarizes current knowledge of indoor air background levels of 1,2‐dichloroethane and potential sources. Recent field data demonstrate that the typical indoor air concentrations for this compound are higher than those reported in the past and may be connected to a larger presence of internationally shipped materials in the current indoor environment than in previous decades. This is an important consideration when evaluating buildings for VI, as background indoor air concentrations of 1,2‐dichloroethane may confound the VI pathway assessment.

Remediation JournalVol. 35(3)
Openalex Percentile: Top 22%
Indoor Air Quality and Microbial Exposure
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.