FECT-OSA: A transformer-enhanced multimodal system for non-contact sleep apnea monitoring

Obstructive sleep apnea (OSA) is a common sleep disorder linked to an increased risk of cardiovascular and neurocognitive disorders. While portable wearables provide a low-cost alternative for OSA detection compared to polysomnography (PSG), their prolonged wear burden, limited accuracy, and susceptibility to motion artifacts hinder practical application. This study introduces FECT-OSA, a non-contact framework that extracts reliable OSA indicators from piezoelectric physiological signals (PPS). FECT-OSA combines three key components: adaptive signal processing, TransUnet, and ConvTransLSTM. Adaptive signal processing utilizes entropy-based selection to determine the most stable input, improving signal robustness. TransUnet improves feature extraction by integrating U-Net’s localization with Transformer-based global modeling. It segments critical spectrogram regions, mitigating motion artifacts and sidelobe interference. ConvTransLSTM integrates CNNs for local feature extraction, a Multimodal Transformer for global alignment, and LSTM for temporal modeling, enhancing OSA detection accuracy. In a study of 34 patients, FECT-OSA achieved 84.79% accuracy, 74.80% sensitivity, and 88.53% specificity, surpassing state-of-the-art portable devices. For severe OSA patients ( A H I ≥ 30 ) , it attains 94.1% accuracy and 90.9% sensitivity/specificity, exceeding traditional methods by 5%–15% in accuracy and 5%–22% in sensitivity. FECT-OSA’s non-contact design minimizes patient discomfort while ensuring high accuracy across varying OSA severities, providing a practical home-based alternative.

Authors

Institutions

Publication Details

Journal
Alexandria Engineering Journal
Published
2025-06-11
DOI
https://doi.org/10.1016/j.aej.2025.05.075
Citations
4
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
4.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FECT-OSA: A transformer-enhanced multimodal system for non-contact sleep apnea monitoring

Mengjiao Hu, Weidong Gao, Dikun Hu, Kai Keng Ang et al.
4 citations
Alexandria Engineering Journal
Obstructive Sleep Apnea Research
4.66
article

FECT-OSA: A transformer-enhanced multimodal system for non-contact sleep apnea monitoring

Mengjiao Hu, Weidong Gao, Dikun Hu, Kai Keng Ang, Yingying Shao, Rong Huang
article en
4 citations

Abstract

Obstructive sleep apnea (OSA) is a common sleep disorder linked to an increased risk of cardiovascular and neurocognitive disorders. While portable wearables provide a low-cost alternative for OSA detection compared to polysomnography (PSG), their prolonged wear burden, limited accuracy, and susceptibility to motion artifacts hinder practical application. This study introduces FECT-OSA, a non-contact framework that extracts reliable OSA indicators from piezoelectric physiological signals (PPS). FECT-OSA combines three key components: adaptive signal processing, TransUnet, and ConvTransLSTM. Adaptive signal processing utilizes entropy-based selection to determine the most stable input, improving signal robustness. TransUnet improves feature extraction by integrating U-Net’s localization with Transformer-based global modeling. It segments critical spectrogram regions, mitigating motion artifacts and sidelobe interference. ConvTransLSTM integrates CNNs for local feature extraction, a Multimodal Transformer for global alignment, and LSTM for temporal modeling, enhancing OSA detection accuracy. In a study of 34 patients, FECT-OSA achieved 84.79% accuracy, 74.80% sensitivity, and 88.53% specificity, surpassing state-of-the-art portable devices. For severe OSA patients ( A H I ≥ 30 ) , it attains 94.1% accuracy and 90.9% sensitivity/specificity, exceeding traditional methods by 5%–15% in accuracy and 5%–22% in sensitivity. FECT-OSA’s non-contact design minimizes patient discomfort while ensuring high accuracy across varying OSA severities, providing a practical home-based alternative.

Alexandria Engineering JournalVol. 128
Agency for Science, Technology and Research (SG), Beijing University of Posts and Telecommunications (CN), Nanyang Technological University (SG), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Institute of Materials Research and Engineering (SG)
Openalex Percentile: Top 5%
Obstructive Sleep Apnea Research
4.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.