Exposure Time Dependence of Operators’ Head Entrance Air Kerma in Interventional Radiology Measured by TLD-100H Chips

Interventional radiology offers minimally invasive procedures guided by real-time imaging, reducing surgical risks and enhancing patient recovery. While beneficial to patients, these advancements increase occupational hazards for physicians due to chronic exposure to ionizing radiation. This exposure raises health risks like radiation-induced cataracts, cardiovascular disease, and cancer. Despite regulations like the European Council Directive 2013/59/EURATOM, which sets limits on whole-body and eye lens doses, no dose limits exist for the brain and meninges, since the brain has traditionally been considered a radioresistant organ. Recent studies, however, have highlighted radiation-induced brain damage, suggesting that meningeal exposure in interventional radiology may be underestimated. This study evaluates the entrance air Cumulative mean annual entrance air kerma to the skullull during interventional radiology procedures, using thermoluminescent dosimeters and controlled exposure simulations. Data were collected by varying the exposure time and analyzing the contribution to the entrance air kerma on each side of the head. The results indicate that, considering the attenuation of the cranial bone, the absorbed dose to the brain, obtained by averaging the head entrance air kerma for the right, front, and left sides of the operator's head, could represent 0.81% to 2.18% of the annual regulatory limit in Italy of 20 mSv for the average annual effective dose of exposed workers (LD 101/2020). These results provide an assessment of brain exposure, highlighting the relatively low but non-negligible contribution of brain irradiation to the overall occupational dose constraint. Additionally, a correlation between entrance air kerma and the Kerma-Area Product was observed, providing a potential method for improved dose estimation and enhanced radiation safety for interventional radiologists.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-11
DOI
https://doi.org/10.3390/s25123666
Citations
2
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exposure Time Dependence of Operators’ Head Entrance Air Kerma in Interventional Radiology Measured by TLD-100H Chips

Salvatore Stilo, Mariagabriella Pugliese, Marco Correra, Luca Tarotto et al.
2 citations
Sensors
Radiation Dose and Imaging
2.72
article

Exposure Time Dependence of Operators’ Head Entrance Air Kerma in Interventional Radiology Measured by TLD-100H Chips

Salvatore Stilo, Mariagabriella Pugliese, Marco Correra, Luca Tarotto, Francesco Fiore, Francesco Manna, Patrizio Antonio Carmosino, Rocco Mottareale
article en
2 citations

Abstract

Interventional radiology offers minimally invasive procedures guided by real-time imaging, reducing surgical risks and enhancing patient recovery. While beneficial to patients, these advancements increase occupational hazards for physicians due to chronic exposure to ionizing radiation. This exposure raises health risks like radiation-induced cataracts, cardiovascular disease, and cancer. Despite regulations like the European Council Directive 2013/59/EURATOM, which sets limits on whole-body and eye lens doses, no dose limits exist for the brain and meninges, since the brain has traditionally been considered a radioresistant organ. Recent studies, however, have highlighted radiation-induced brain damage, suggesting that meningeal exposure in interventional radiology may be underestimated. This study evaluates the entrance air Cumulative mean annual entrance air kerma to the skullull during interventional radiology procedures, using thermoluminescent dosimeters and controlled exposure simulations. Data were collected by varying the exposure time and analyzing the contribution to the entrance air kerma on each side of the head. The results indicate that, considering the attenuation of the cranial bone, the absorbed dose to the brain, obtained by averaging the head entrance air kerma for the right, front, and left sides of the operator's head, could represent 0.81% to 2.18% of the annual regulatory limit in Italy of 20 mSv for the average annual effective dose of exposed workers (LD 101/2020). These results provide an assessment of brain exposure, highlighting the relatively low but non-negligible contribution of brain irradiation to the overall occupational dose constraint. Additionally, a correlation between entrance air kerma and the Kerma-Area Product was observed, providing a potential method for improved dose estimation and enhanced radiation safety for interventional radiologists.

SensorsVol. 25(12)
Istituto Nazionale di Fisica Nucleare (IT), Federico II University Hospital (IT), Tecnologie Avanzate (Italy) (IT), Istituto Nazionale Tumori IRCCS "Fondazione G. Pascale" (IT)
Openalex Percentile: Top 10%
Radiation Dose and Imaging
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.