Investigation of Factors Influencing the End-of-Line Partial Discharge Testing of Electrical Machines

Recurrent partial discharges (PD) in the insulation system of electrical machines result in accelerated insulation degeneration and a premature breakdown. Determining the repetitive PD inception voltage (RPDIV) of stators for automotive traction machines at the end of the production line following IEC/TS 61934 is mandatory to ensure a PD-free operation over the service life. The RPDIV depends on various influencing factors, which impedes the comparability of RPDIV results from different test systems. This paper introduces a PD detection platform to systematically investigate the RPDIV differences between two exemplary commercial PD testers. The proposed fusion between the PD signals received by a Horn antenna and a high-frequency current transformer is a suitable reference with a higher PD detection capability than the state-of-the-art systems. Three main influencing factors are identified to explain the RPDIV differences of up to 15 % between the commercial PD testers. The first one is the sensitivity of the antennas for PD detection, which is affected by the antenna design, the relative position to the stator, and the frequency band utilized in the signal processing. Second, differences in the rise time of the high-voltage surge pulses between 220 and 670 ns do not result in a consistent overall RPDIV trend. However, the RPDIV tends to increase with a longer rise time for some stators. Finally, measuring the test voltage directly at the stator terminals or estimating the actual voltage by correction factors is essential to avoid RPDIV differences caused by an inaccurate voltage measurement.

Authors

Institutions

Publication Details

Published
2025-04-09
DOI
https://doi.org/10.1109/wemdcd61816.2025.11014117
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Factors Influencing the End-of-Line Partial Discharge Testing of Electrical Machines

Peer Stenzel, Andreas Rauscher, Christian Endisch
1 citations
High voltage insulation and dielectric phenomena
0.52
article

Investigation of Factors Influencing the End-of-Line Partial Discharge Testing of Electrical Machines

Peer Stenzel, Andreas Rauscher, Christian Endisch
article en
1 citations

Abstract

Recurrent partial discharges (PD) in the insulation system of electrical machines result in accelerated insulation degeneration and a premature breakdown. Determining the repetitive PD inception voltage (RPDIV) of stators for automotive traction machines at the end of the production line following IEC/TS 61934 is mandatory to ensure a PD-free operation over the service life. The RPDIV depends on various influencing factors, which impedes the comparability of RPDIV results from different test systems. This paper introduces a PD detection platform to systematically investigate the RPDIV differences between two exemplary commercial PD testers. The proposed fusion between the PD signals received by a Horn antenna and a high-frequency current transformer is a suitable reference with a higher PD detection capability than the state-of-the-art systems. Three main influencing factors are identified to explain the RPDIV differences of up to 15 % between the commercial PD testers. The first one is the sensitivity of the antennas for PD detection, which is affected by the antenna design, the relative position to the stator, and the frequency band utilized in the signal processing. Second, differences in the rise time of the high-voltage surge pulses between 220 and 670 ns do not result in a consistent overall RPDIV trend. However, the RPDIV tends to increase with a longer rise time for some stators. Finally, measuring the test voltage directly at the stator terminals or estimating the actual voltage by correction factors is essential to avoid RPDIV differences caused by an inaccurate voltage measurement.

Audi (Germany) (DE), Technische Hochschule Ingolstadt (DE)
Openalex Percentile: Top 37%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.