Evaluating Disposable Isolation Gown Liquid Barrier Test Methods for Relevance to Healthcare

Healthcare staff rely on isolation gowns to provide a degree of protection against cross contamination from blood or body fluids. Gowns that meet standardized liquid barrier penetration test methods provide staff with a presumed assurance of safety. However, these test methods-namely impact penetration and resistance to hydrostatic pressure-were not drafted with personal protective equipment in mind and therefore may be inappropriate for testing products intended for use in a healthcare environment. This study found that adjusting testing parameters to better simulate clinical conditions altered the measured performance outcomes of the gowns. Specifically, increasing the temperature of the gown material's preconditioning environment or test liquid resulted in statistically significant variations in results. Further, although hydrostatic pressure resistance is measured by the appearance of a third liquid droplet on the inner surface of the gown material, the first two droplets appeared at significantly lower pressures and likely would constitute contamination of healthcare staff. The results indicated that current isolation gown test protocols and regulations should be reevaluated to more accurately reflect healthcare scenarios and improve alignment with expected barrier performance.

Authors

Institutions

Publication Details

Journal
Biomedical Instrumentation & Technology
Published
2025-04-01
DOI
https://doi.org/10.2345/0899-8205-59.1.108
Primary Topic
Infection Control in Healthcare
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Disposable Isolation Gown Liquid Barrier Test Methods for Relevance to Healthcare

Jeremy F. Suggs, James H. Davis, Julie Miller, Karen Haberland et al.
Biomedical Instrumentation & Technology
Infection Control in Healthcare
article

Evaluating Disposable Isolation Gown Liquid Barrier Test Methods for Relevance to Healthcare

Jeremy F. Suggs, James H. Davis, Julie Miller, Karen Haberland, Mukui Mutunga
article en

Abstract

Healthcare staff rely on isolation gowns to provide a degree of protection against cross contamination from blood or body fluids. Gowns that meet standardized liquid barrier penetration test methods provide staff with a presumed assurance of safety. However, these test methods-namely impact penetration and resistance to hydrostatic pressure-were not drafted with personal protective equipment in mind and therefore may be inappropriate for testing products intended for use in a healthcare environment. This study found that adjusting testing parameters to better simulate clinical conditions altered the measured performance outcomes of the gowns. Specifically, increasing the temperature of the gown material's preconditioning environment or test liquid resulted in statistically significant variations in results. Further, although hydrostatic pressure resistance is measured by the appearance of a third liquid droplet on the inner surface of the gown material, the first two droplets appeared at significantly lower pressures and likely would constitute contamination of healthcare staff. The results indicated that current isolation gown test protocols and regulations should be reevaluated to more accurately reflect healthcare scenarios and improve alignment with expected barrier performance.

Biomedical Instrumentation & TechnologyVol. 59(1)
ECRI Institute (US)
Drexel University
Openalex Percentile: Top 83%
Infection Control in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.