SHM system development for molten salt test loop

Ultrasonic structural health monitoring (SHM) systems can detect degrading material properties based on changing wave speeds. In harsh environments like molten salt reactors and allied test loops, the transducers must be sufficiently robust to survive, and guided waves facilitate minimizing the number of transducers. The L (0, 2) guided wave mode can propagate long distances in the Ni-based alloy 600 tubing used for a molten salt thermal convection loop. The sensitivity of the L (0, 2) group velocity to material degradation associated with the corrosive attack of molten salt is assessed by modeling and ex situ guided wave speed measurements from alloy 600 tubing used in static salt tests. Guided wave testing is performed on dry tubing at room temperature. Microscopy is performed after guided wave testing to document the corrosive attack. At driving frequencies of 490 and 680 kHz, the group velocities are shown to decrease and increase, respectively, for small amounts of material degradation on the inner diameter of the tubing. These opposite trends in group velocity are anticipated to provide a sensitive characteristic for SHM. Although the data are somewhat limited, the wave speed of the more dispersive 680 kHz frequency appears to be more sensitive to corrosive attack, with a possible threshold in the 50–100 µm range.

Authors

Institutions

Publication Details

Journal
Structural Health Monitoring
Published
2025-06-11
DOI
https://doi.org/10.1177/14759217251339441
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SHM system development for molten salt test loop

Bruce A. Pint, Cliff J. Lissenden, Indu Saxena
Structural Health Monitoring
Ultrasonics and Acoustic Wave Propagation
article

SHM system development for molten salt test loop

Bruce A. Pint, Cliff J. Lissenden, Indu Saxena
article en

Abstract

Ultrasonic structural health monitoring (SHM) systems can detect degrading material properties based on changing wave speeds. In harsh environments like molten salt reactors and allied test loops, the transducers must be sufficiently robust to survive, and guided waves facilitate minimizing the number of transducers. The L (0, 2) guided wave mode can propagate long distances in the Ni-based alloy 600 tubing used for a molten salt thermal convection loop. The sensitivity of the L (0, 2) group velocity to material degradation associated with the corrosive attack of molten salt is assessed by modeling and ex situ guided wave speed measurements from alloy 600 tubing used in static salt tests. Guided wave testing is performed on dry tubing at room temperature. Microscopy is performed after guided wave testing to document the corrosive attack. At driving frequencies of 490 and 680 kHz, the group velocities are shown to decrease and increase, respectively, for small amounts of material degradation on the inner diameter of the tubing. These opposite trends in group velocity are anticipated to provide a sensitive characteristic for SHM. Although the data are somewhat limited, the wave speed of the more dispersive 680 kHz frequency appears to be more sensitive to corrosive attack, with a possible threshold in the 50–100 µm range.

Structural Health Monitoring
Oak Ridge National Laboratory (US), Pennsylvania State University (US)
U.S. Department of Energy
Openalex Percentile: Top 85%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.