Insulation Performance of a Hermetically Sealed and Process Cooled Motor-Compressor Exposed to Water-Saturated Natural Gas Environments

In this paper the impact on the dielectric performance of an epoxy-mica-composite insulation system exposed to a water-saturated hydrocarbon gas environment under pressure, as used in a hermetically sealed process-cooled motor-compressor, is presented. Two litz-wire loops, both insulated with the same system, were built to allow for the simultaneous application of direct current (DC) during the aging process, and thus for the investigation on the effect of the resulting copper-based losses during exposure. Results for both the DC-heated loop and the passive control loop are presented. The measured dielectric response shows clear recovery and eventual preservation for the DC-heated loop in comparison to the wetted-control-loop. The effect of multiple heating and depressurization cycles is also presented.

Authors

Institutions

Publication Details

Published
2025-04-09
DOI
https://doi.org/10.1109/wemdcd61816.2025.11014136
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insulation Performance of a Hermetically Sealed and Process Cooled Motor-Compressor Exposed to Water-Saturated Natural Gas Environments

Svend Tarald Kibsgaard, James Borg-Bartolo, Jeremy Lepelley, Gunnar Berg-Karlsen
Aerodynamics and Fluid Dynamics Research
article

Insulation Performance of a Hermetically Sealed and Process Cooled Motor-Compressor Exposed to Water-Saturated Natural Gas Environments

Svend Tarald Kibsgaard, James Borg-Bartolo, Jeremy Lepelley, Gunnar Berg-Karlsen
article en

Abstract

In this paper the impact on the dielectric performance of an epoxy-mica-composite insulation system exposed to a water-saturated hydrocarbon gas environment under pressure, as used in a hermetically sealed process-cooled motor-compressor, is presented. Two litz-wire loops, both insulated with the same system, were built to allow for the simultaneous application of direct current (DC) during the aging process, and thus for the investigation on the effect of the resulting copper-based losses during exposure. Results for both the DC-heated loop and the passive control loop are presented. The measured dielectric response shows clear recovery and eventual preservation for the DC-heated loop in comparison to the wetted-control-loop. The effect of multiple heating and depressurization cycles is also presented.

SINTEF (NO), Aker (Norway) (NO), Aker BP (Norway) (NO), Equinor (Norway) (NO)
Openalex Percentile: Top 82%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.