Proton Radiation Test of Gamma-Ray Transients Monitor (GTM) on Board Formosat-8B

The Gamma-ray Transients Monitor (GTM) is a secondary payload on board Formosat-8B (FS-8B), a Taiwanese remote-sensing satellite, to monitor Gamma Ray Bursts (GRBs) and other bright gamma-ray transients in the energy range from 50 keV to 2 MeV. The readout module of GTM was built with all commercial-off-the-shelf (COTS) components to meet very restricted power and size requirements, including frontend analog devices, switching and linear regulators, interface devices and field programmable gate array (FPGA). Therefore, a 221 MeV proton radiation test in the Proton and Radiation Therapy Center of Chang Gung Memorial Hospital, Taiwan was conducted to ensure the reliability of GTM readout module operated in the low earth orbit (LEO) environment. The accumulated 221 MeV proton fluence in this test was 1.03×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sup> proton/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>, equivalent to 5.6 krad(Si), with average proton flux 2.50×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">7</sup> proton/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>/sec. There was not any catastrophic event observed in this proton radiation test. Only soft error events were seen with reasonably low cross-sections.

Authors

Institutions

Publication Details

Published
2024-09-19
DOI
https://doi.org/10.1109/radecs61975.2024.11017550
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proton Radiation Test of Gamma-Ray Transients Monitor (GTM) on Board Formosat-8B

Chien-You Huang, Hsiang‐Kuang Chang, Tzu-Hsuan Lin, Yonghua Chen et al.
Nuclear Physics and Applications
article

Proton Radiation Test of Gamma-Ray Transients Monitor (GTM) on Board Formosat-8B

Chien-You Huang, Hsiang‐Kuang Chang, Tzu-Hsuan Lin, Yonghua Chen, Chun‐Wei Wu, Shyh‐Horng Chiou, Chih‐Hsun Lin, Che-Chih Tsao, Hao-Min Chang, Chih-En Wu, An-Hsuan Feng
article en

Abstract

The Gamma-ray Transients Monitor (GTM) is a secondary payload on board Formosat-8B (FS-8B), a Taiwanese remote-sensing satellite, to monitor Gamma Ray Bursts (GRBs) and other bright gamma-ray transients in the energy range from 50 keV to 2 MeV. The readout module of GTM was built with all commercial-off-the-shelf (COTS) components to meet very restricted power and size requirements, including frontend analog devices, switching and linear regulators, interface devices and field programmable gate array (FPGA). Therefore, a 221 MeV proton radiation test in the Proton and Radiation Therapy Center of Chang Gung Memorial Hospital, Taiwan was conducted to ensure the reliability of GTM readout module operated in the low earth orbit (LEO) environment. The accumulated 221 MeV proton fluence in this test was 1.03×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sup> proton/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>, equivalent to 5.6 krad(Si), with average proton flux 2.50×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">7</sup> proton/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>/sec. There was not any catastrophic event observed in this proton radiation test. Only soft error events were seen with reasonably low cross-sections.

National Tsing Hua University (TW), Institute of Physics, Academia Sinica (TW), Linkou Chang Gung Memorial Hospital (TW)
Openalex Percentile: Top 64%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.