Learning‐Based Rapid Phase‐Aberration Correction and Control for Robot‐Assisted MRI‐Guided Low‐/High‐Intensity Focused Ultrasound Treatments

ABSTRACT Magnetic resonance imaging (MRI)‐guided focused ultrasound (MRg‐FUS) is an effective and noninvasive procedure for treating diseases such as neurological disorders. Phase adjustment on ultrasound transducers can only achieve a limited focal‐spot steering range. When treating large abdominopelvic targets, mechanical adjustment on the transducers' position and orientation is the prerequisite for enlarging the steering range. Therefore, we previously designed an MRI‐guided robot to manipulate the transducers to offer sufficient focal‐spot movement range. This could provide more modulation solutions to constructive ultrasound interference. However, full‐wave ultrasound propagation inside a patient's heterogeneous abdominal media is complex and nonlinear, posing significant challenges in ultrasound modulation and beam motion control. Here, we propose a novel learning‐based phase‐aberration correction and model‐free control framework for robot‐assisted MRg‐FUS treatments. The correction policy guarantees rapid aberration compensation within 5.0 ms. Submillimeter refocusing accuracy is achieved in both the liver (0.32 mm) and pancreas (0.51 mm), meeting clinical requirements for focal targeting. Our controller can accommodate nonlinear phase actuation with fast convergence (< 5.7 ms) and ensure accurate positional tracking with a mean error of 0.26 mm, without prior knowledge of inhomogeneous media. Compared with the conventional model‐based method, it contributes to 61.77%–70.39% mean error reduction without requiring model parameter tuning.

Authors

Institutions

Publication Details

Journal
Journal of Field Robotics
Published
2025-06-11
DOI
https://doi.org/10.1002/rob.22606
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Learning‐Based Rapid Phase‐Aberration Correction and Control for Robot‐Assisted MRI‐Guided Low‐/High‐Intensity Focused Ultrasound Treatments

Bohao Zhu, Hing‐Chiu Chang, James Lam, Jing Dai et al.
Journal of Field Robotics
Ultrasound and Hyperthermia Applications
article

Learning‐Based Rapid Phase‐Aberration Correction and Control for Robot‐Assisted MRI‐Guided Low‐/High‐Intensity Focused Ultrasound Treatments

Bohao Zhu, Hing‐Chiu Chang, James Lam, Jing Dai, Ka‐Wai Kwok, Liyuan Liang, Xiaochen Xie, Xiaomei Wang
article en

Abstract

ABSTRACT Magnetic resonance imaging (MRI)‐guided focused ultrasound (MRg‐FUS) is an effective and noninvasive procedure for treating diseases such as neurological disorders. Phase adjustment on ultrasound transducers can only achieve a limited focal‐spot steering range. When treating large abdominopelvic targets, mechanical adjustment on the transducers' position and orientation is the prerequisite for enlarging the steering range. Therefore, we previously designed an MRI‐guided robot to manipulate the transducers to offer sufficient focal‐spot movement range. This could provide more modulation solutions to constructive ultrasound interference. However, full‐wave ultrasound propagation inside a patient's heterogeneous abdominal media is complex and nonlinear, posing significant challenges in ultrasound modulation and beam motion control. Here, we propose a novel learning‐based phase‐aberration correction and model‐free control framework for robot‐assisted MRg‐FUS treatments. The correction policy guarantees rapid aberration compensation within 5.0 ms. Submillimeter refocusing accuracy is achieved in both the liver (0.32 mm) and pancreas (0.51 mm), meeting clinical requirements for focal targeting. Our controller can accommodate nonlinear phase actuation with fast convergence (< 5.7 ms) and ensure accurate positional tracking with a mean error of 0.26 mm, without prior knowledge of inhomogeneous media. Compared with the conventional model‐based method, it contributes to 61.77%–70.39% mean error reduction without requiring model parameter tuning.

Journal of Field RoboticsVol. 42(7)
Chinese University of Hong Kong (HK), Harbin Institute of Technology (CN), Rehab-Robotics (China) (CN), University of Duisburg-Essen (DE), University of Hong Kong (HK)
Openalex Percentile: Top 88%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.