Transcutaneous CO2 Measurement in an Adult Long-Term Ventilation (LTV) Service

<b>Background</b>: Transcutaneous CO<sub>2</sub> (TcCO<sub>2</sub>) measurement is widely used in the diagnosis and monitoring of ventilatory failure. Robust data on the success rates of measurement is scant. We aimed to discern the factors affecting the success rate of TcCO<sub>2</sub> measurement in a regional LTV service. <b>Methods</b>: Patients undergoing TcCO<sub>2</sub> measurement between October 2019 and January 2022 were identified retrospectively. Notes were analysed for basic demographics, indications for TcCO<sub>2</sub> measurement, measurement outcome, device used (Radiometer TCM5 or Sentec, based on availability), setup (self, carer, or clinician), inpatient or domiciliary study, and number of TcCO<sub>2</sub> measurement attempts occurred. Statistical comparisons were made by Fisher's exact test. <b>Results</b>: We identified 435 recording events on 288 patients, mean age of 53, and 56% were males. A total of 189 (66%) had a neuromuscular disorder (NMD). The commonest indications for TcCO<sub>2</sub> measurement were 'assessing ventilatory failure' (43%) in treatment-naïve patients and 'adequacy of ventilation therapy due to persistent symptoms' (26%) in those established on LTV. Over 80% of our recording events were applied by patients or their carers. Overall, TCM5 devices had statistically higher successful recording rates (197/268, 73.5%) than Sentec (100/165, 60.6%) [<i>p</i> = 0.0056]. In domiciliary studies, TCM5's success rate of 187/253 (73.9%) versus Sentec's 94/154 (61.0%) was significantly better [<i>p</i> = 0.0079]. The success rate of each measurement attempt ranged between 62.9 and 67.0%, with up to three attempts on each subject. <b>Conclusions</b>: Home TcCO<sub>2</sub> is helpful in managing those with respiratory failure. Repeating tests after initial failure of recording is worthwhile. There may be differences in performance across devices which warrants further study.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-06-11
DOI
https://doi.org/10.3390/jcm14124137
Citations
1
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcutaneous CO2 Measurement in an Adult Long-Term Ventilation (LTV) Service

J C Rodger, Ching Khai Ho, Kenneth K. Kaiser, Nicholas D. Lane et al.
1 citations
Journal of Clinical Medicine
Respiratory Support and Mechanisms
1.52
article

Transcutaneous CO2 Measurement in an Adult Long-Term Ventilation (LTV) Service

J C Rodger, Ching Khai Ho, Kenneth K. Kaiser, Nicholas D. Lane, Alison Armstrong, Y Madhu, Richard Davidson, Ben Messer, Kayla George, Anthony De Soyza, Wei Hann Ong, Ross Fowkes, Hilary Tedd, Peter Ireland
article en
1 citations

Abstract

<b>Background</b>: Transcutaneous CO<sub>2</sub> (TcCO<sub>2</sub>) measurement is widely used in the diagnosis and monitoring of ventilatory failure. Robust data on the success rates of measurement is scant. We aimed to discern the factors affecting the success rate of TcCO<sub>2</sub> measurement in a regional LTV service. <b>Methods</b>: Patients undergoing TcCO<sub>2</sub> measurement between October 2019 and January 2022 were identified retrospectively. Notes were analysed for basic demographics, indications for TcCO<sub>2</sub> measurement, measurement outcome, device used (Radiometer TCM5 or Sentec, based on availability), setup (self, carer, or clinician), inpatient or domiciliary study, and number of TcCO<sub>2</sub> measurement attempts occurred. Statistical comparisons were made by Fisher's exact test. <b>Results</b>: We identified 435 recording events on 288 patients, mean age of 53, and 56% were males. A total of 189 (66%) had a neuromuscular disorder (NMD). The commonest indications for TcCO<sub>2</sub> measurement were 'assessing ventilatory failure' (43%) in treatment-naïve patients and 'adequacy of ventilation therapy due to persistent symptoms' (26%) in those established on LTV. Over 80% of our recording events were applied by patients or their carers. Overall, TCM5 devices had statistically higher successful recording rates (197/268, 73.5%) than Sentec (100/165, 60.6%) [<i>p</i> = 0.0056]. In domiciliary studies, TCM5's success rate of 187/253 (73.9%) versus Sentec's 94/154 (61.0%) was significantly better [<i>p</i> = 0.0079]. The success rate of each measurement attempt ranged between 62.9 and 67.0%, with up to three attempts on each subject. <b>Conclusions</b>: Home TcCO<sub>2</sub> is helpful in managing those with respiratory failure. Repeating tests after initial failure of recording is worthwhile. There may be differences in performance across devices which warrants further study.

Journal of Clinical MedicineVol. 14(12)
Royal Victoria Infirmary (GB), Newcastle upon Tyne Hospitals NHS Foundation Trust (GB), Newcastle University (GB)
Openalex Percentile: Top 17%
Respiratory Support and Mechanisms
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.