Total Ionizing Dose Characterization of Advanced Latch-Up Current Limiter ASIC

This paper presents the results of the Total Ionizing Dose characterization of the Analog Current Control Loop implemented within the SKY-IC-RHLCL-A1 Latch-Up current limiter application-specific integrated circuit. Given the criticality of Single Event Latch-ups in satellite platforms, the use of safeguard circuits such as latching current limiters is essential. This work focuses on performance and resilience of the Analog Current Control Loop, which is responsible for the measurements of protected load current and current limitation in case of a Single Event Latch-up. The characterization results provide valuable insights into the behavior and reliability of the Latch-up current limiter under the irradiation exposure. Five out of six biased current limiters were able to function up to 40 krad(Si) of Total Ionizing Dose, whereas one experienced failure at 22 krad(Si) due to startup circuit failure. Beyond 40 krad(Si), the devices began to fail gradually, but regained functionality after the annealing process.

Authors

Publication Details

Published
2024-09-19
DOI
https://doi.org/10.1109/radecs61975.2024.11017530
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Total Ionizing Dose Characterization of Advanced Latch-Up Current Limiter ASIC

Iztok Kramberger, Bojan Kotnik, Gianluca Furano, Matic Erker et al.
Integrated Circuits and Semiconductor Failure Analysis
article

Total Ionizing Dose Characterization of Advanced Latch-Up Current Limiter ASIC

Iztok Kramberger, Bojan Kotnik, Gianluca Furano, Matic Erker, B. Glass, Antonios Tavoularis, David Selčan, Mihalis Tourloukis, Dejan Gačnik, Liam James Murphy, Andrej Hudrap
article en

Abstract

This paper presents the results of the Total Ionizing Dose characterization of the Analog Current Control Loop implemented within the SKY-IC-RHLCL-A1 Latch-Up current limiter application-specific integrated circuit. Given the criticality of Single Event Latch-ups in satellite platforms, the use of safeguard circuits such as latching current limiters is essential. This work focuses on performance and resilience of the Analog Current Control Loop, which is responsible for the measurements of protected load current and current limitation in case of a Single Event Latch-up. The characterization results provide valuable insights into the behavior and reliability of the Latch-up current limiter under the irradiation exposure. Five out of six biased current limiters were able to function up to 40 krad(Si) of Total Ionizing Dose, whereas one experienced failure at 22 krad(Si) due to startup circuit failure. Beyond 40 krad(Si), the devices began to fail gradually, but regained functionality after the annealing process.

Openalex Percentile: Top 72%
Integrated Circuits and Semiconductor Failure Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.