Utilising highly conductive TPU “sticks” for facile and low-cost electroanalysis

Rapid, on-site analysis of environmental contaminants necessitates the use of cost-effective and straightforward apparatus to encourage widespread adoption and align with the United Nations Sustainable Development Goal 6: Clean Water and Sanitation. In this work, we report the development of highly conductive thermoplastic polyurethane (TPU) filaments that can be easily cut and assembled into "sticks", functioning as standalone rod-like working electrodes for electrochemical and electroanalytical applications. Using TPU as the base polymer, filaments filled with 35, 40, and 45 wt% carbon black (CB) were fabricated and characterised both physicochemically and electrochemically at different lengths (2.5, 5 and 10 mm). Among these, the 45 wt% CB filaments demonstrated the best electrode performance. Interestingly, due to morphological differences between the cross-section and the outer surface of the filament, extending the length of the filament sticks to 10 mm resulted in significant splitting of electrochemical peaks. Consequently, 5 mm sticks were optimised and employed for the electroanalytical detection of acetaminophen, achieving a linear detection range of 5-800 μM, a detection limit of 1.74 μM, and a quantification limit of 5.70 μM. These sticks were further validated by successfully detecting acetaminophen in tap and river water samples. This work introduces an innovative approach to reducing costs and simplifying on-site electrochemical analysis by using predefined lengths of conductive plastic filaments, which can be conveniently transported and stored on a spool until needed. The simplicity and affordability of this method enhance the commercial viability of electroanalytical sensing technologies.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2025-01-01
DOI
https://doi.org/10.1039/d5an00472a
Citations
6
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilising highly conductive TPU “sticks” for facile and low-cost electroanalysis

Craig E. Banks, Robert D. Crapnell, Elena Bernalte, Rodrigo A.A. Muñoz et al.
6 citations
The Analyst
Electrochemical sensors and biosensors
4.38
article

Utilising highly conductive TPU “sticks” for facile and low-cost electroanalysis

Craig E. Banks, Robert D. Crapnell, Elena Bernalte, Rodrigo A.A. Muñoz, Ana C.M. Oliveira
article en
6 citations

Abstract

Rapid, on-site analysis of environmental contaminants necessitates the use of cost-effective and straightforward apparatus to encourage widespread adoption and align with the United Nations Sustainable Development Goal 6: Clean Water and Sanitation. In this work, we report the development of highly conductive thermoplastic polyurethane (TPU) filaments that can be easily cut and assembled into "sticks", functioning as standalone rod-like working electrodes for electrochemical and electroanalytical applications. Using TPU as the base polymer, filaments filled with 35, 40, and 45 wt% carbon black (CB) were fabricated and characterised both physicochemically and electrochemically at different lengths (2.5, 5 and 10 mm). Among these, the 45 wt% CB filaments demonstrated the best electrode performance. Interestingly, due to morphological differences between the cross-section and the outer surface of the filament, extending the length of the filament sticks to 10 mm resulted in significant splitting of electrochemical peaks. Consequently, 5 mm sticks were optimised and employed for the electroanalytical detection of acetaminophen, achieving a linear detection range of 5-800 μM, a detection limit of 1.74 μM, and a quantification limit of 5.70 μM. These sticks were further validated by successfully detecting acetaminophen in tap and river water samples. This work introduces an innovative approach to reducing costs and simplifying on-site electrochemical analysis by using predefined lengths of conductive plastic filaments, which can be conveniently transported and stored on a spool until needed. The simplicity and affordability of this method enhance the commercial viability of electroanalytical sensing technologies.

The AnalystVol. 150(14)
Manchester Metropolitan University (GB), Universidade Federal de Uberlândia (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Horizon 2020 Framework Programme, HORIZON EUROPE Framework Programme, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 6%
Electrochemical sensors and biosensors
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.