Optimizing Antioxidant Synergy for the Restoration of Aged FR3 Transformer Fluid

This study focuses on the restoration of aged FR3 transformer fluid by optimizing antioxidant formulations to enhance its dielectric and physicochemical properties. A composite antioxidant approach, incorporating tertiary butylhydroquinone (TBHQ), butylated hydroxytoluene (BHT), alpha-tocopherol, and citric acid, is employed to improve fluid performance. The efficacy of various antioxidant combinations is evaluated based on key parameters, including breakdown voltage, acidity, flash point, fire point, and dielectric dissipation factor. Response Surface Methodology (RSM) is utilized to optimize the antioxidant blend, while ANOVA (Analysis of Variance) assesses the statistical significance of the developed models. The optimized antioxidant combination improved breakdown voltage by 45.18% (R² = 0.9529), reduced acidity by 59.09% (R² = 0.9763), and enhanced flash by (37.17%) and fire points by 30.85% (R² = 0.9454 and 0.8022, respectively). Dielectric dissipation factor also showed strong improvement (24.32%) (R² = 0.9534). The high R², adjusted R², and adequate precision values indicate robust model reliability and predictive capability. While breakdown voltage exhibited acceptable lack of fit (p = 0.0255), other responses showed non-significant lack of fit, confirming model adequacy. These findings highlight the method’s effectiveness, synergistic antioxidant effects, and potential for sustainable transformer maintenance.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-06-11
DOI
https://doi.org/10.1109/tdei.2025.3578578
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Antioxidant Synergy for the Restoration of Aged FR3 Transformer Fluid

R. Madavan, Abderrahmane Béroual, S. S. Kumaresh
IEEE Transactions on Dielectrics and Electrical Insulation
Power Transformer Diagnostics and Insulation
article

Optimizing Antioxidant Synergy for the Restoration of Aged FR3 Transformer Fluid

R. Madavan, Abderrahmane Béroual, S. S. Kumaresh
article en

Abstract

This study focuses on the restoration of aged FR3 transformer fluid by optimizing antioxidant formulations to enhance its dielectric and physicochemical properties. A composite antioxidant approach, incorporating tertiary butylhydroquinone (TBHQ), butylated hydroxytoluene (BHT), alpha-tocopherol, and citric acid, is employed to improve fluid performance. The efficacy of various antioxidant combinations is evaluated based on key parameters, including breakdown voltage, acidity, flash point, fire point, and dielectric dissipation factor. Response Surface Methodology (RSM) is utilized to optimize the antioxidant blend, while ANOVA (Analysis of Variance) assesses the statistical significance of the developed models. The optimized antioxidant combination improved breakdown voltage by 45.18% (R² = 0.9529), reduced acidity by 59.09% (R² = 0.9763), and enhanced flash by (37.17%) and fire points by 30.85% (R² = 0.9454 and 0.8022, respectively). Dielectric dissipation factor also showed strong improvement (24.32%) (R² = 0.9534). The high R², adjusted R², and adequate precision values indicate robust model reliability and predictive capability. While breakdown voltage exhibited acceptable lack of fit (p = 0.0255), other responses showed non-significant lack of fit, confirming model adequacy. These findings highlight the method’s effectiveness, synergistic antioxidant effects, and potential for sustainable transformer maintenance.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 33(1)
Université Claude Bernard Lyon 1 (FR), École Centrale de Lyon (FR), Centre National de la Recherche Scientifique (FR), Sri Chandrasekharendra Saraswathi Viswa Mahavidyalaya (IN), Chhatrapati Shahu Ji Maharaj University (IN), Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram (IN), Laboratoire Ampère (FR)
Openalex Percentile: Top 89%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.