A Fourth-Order Tunable Bandwidth <i>G<sub>m</sub> </i>-C Filter for ECG Detection Achieving −7.9 dBV IIP3 Under a 0.5 V Supply
This article introduces a fourth-order <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$G_{m}$</tex-math> </inline-formula>-C low-pass filter for ECG detection that achieves high linearity despite operating under a 0.5 V supply by 1) placing the differential pairs (DPs) of the employed <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$G_{m}$</tex-math> </inline-formula> stages in a two-loop feedback structure, 2) employing body-driven rather than gate-driven <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$G_{m}$</tex-math> </inline-formula> DPs, and 3) using current mirrors in place of cascoded transistors in a conventional <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$G_{m}$</tex-math> </inline-formula> stage. Measurement results of a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.18~\mu $</tex-math> </inline-formula>m CMOS prototype show that the proposed filter, operating with a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$V_{\text {DD}}$</tex-math> </inline-formula> of 0.5 V, achieves an third-order harmonic distortion (HD3) below −40 dB for input amplitudes up to 340 mV<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pp</sub>. With an integrated noise of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$154.7~\mu $</tex-math> </inline-formula>V<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rms</sub> over a 240-Hz bandwidth, the filter exhibits a dynamic range (DR) of 53.6 dB, which is competitive with previously reported works.
Authors
- Farzan Rezaei (ORCID: https://orcid.org/0000-0002-3791-926X)
- Loai G. Salem (ORCID: https://orcid.org/0000-0002-5652-5098)
Institutions
- University of California, Santa Barbara (US)
Publication Details
- Journal
- IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Published
- 2025-06-11
- DOI
- https://doi.org/10.1109/tvlsi.2025.3576360
- Citations
- 2
- Primary Topic
- ECG Monitoring and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 2.78