Numerical Investigation of Hybrid Immersion Cooling Strategies for Battery Packs in Light Electric Vehicles

This work investigates a new hybrid thermal management system (TMS) for light electric vehicle (LEV) battery packs that uses dielectric liquid immersion cooling, heat pipes and fins to effectively control lithium-ion battery (LIB) thermal load.Different commercial dielectric oil chemistries (Cargill DE-11772 and EF-3221, LK-STO50, and MIVOLT-DFK) are evaluated as heat transfer fluids (HTFs) and compared with air and deionised water as benchmark.Additionally, the effects of heat pipe diameters (4 mm, 6 mm, and 8 mm) and the number of fins (1, 2, 3, and 5) are analysed for two configurations: fins evenly distributed along the heat pipe and fins placed only on the upper half.A 3D steady-state CFD model is developed in Ansys 2024R2 to simulate the proposed TMS for a 4S4P (14.8V, 10 Ah) Lithium-Nickel Manganese Cobalt (NMC) battery pack.Under typical 2C discharge rate, the model examines the TMS thermal performance when simulating heat transfer with and without buoyancy effects.Buoyancy improves cooling performance, especially for viscous fluids, lowering battery, HTF, and heat sink temperatures by 20%.With modest LIB heat generation rates (up to 25 kW/m), the TMS ensures effective cooling with minimum temperature increase.However, when reaching heat generation rates up to 100 kW/m, the battery temperature reaches 91.13C, revealing the system's cooling capability limitations.The study examines the effect of changing heat sink and insulation equivalent convective heat transfer coefficients.Increasing the heat sink coefficient from 10 to 100 W/mK lowers the battery temperature from 138C to 49C, while increasing the insulation equivalent heat transfer coefficient from 1 to 50 W/mK lowers battery temperature from 92C to 46C.Also, the effect of heat pipes diameter and fins number and vertical distribution is analysed, pointing to the design with 5 evenly distributed fins to be the best thermally performing while limiting additional TMS mass.This study shows that the hybrid TMS using heat pipes, fins, immersion cooling improves compact LEV safety, performance, and battery longevity under high-demand situations.

Authors

Publication Details

Journal
Journal of Fluid Flow Heat and Mass Transfer
Published
2025-01-01
DOI
https://doi.org/10.11159/jffhmt.2025.024
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigation of Hybrid Immersion Cooling Strategies for Battery Packs in Light Electric Vehicles

Jack R. Panter, Gordhan Das Valasai, Stefano Landini, Anindita Roy et al.
Journal of Fluid Flow Heat and Mass Transfer
Advanced Battery Technologies Research
article

Numerical Investigation of Hybrid Immersion Cooling Strategies for Battery Packs in Light Electric Vehicles

Jack R. Panter, Gordhan Das Valasai, Stefano Landini, Anindita Roy, Mohammad Ismail
article en

Abstract

This work investigates a new hybrid thermal management system (TMS) for light electric vehicle (LEV) battery packs that uses dielectric liquid immersion cooling, heat pipes and fins to effectively control lithium-ion battery (LIB) thermal load.Different commercial dielectric oil chemistries (Cargill DE-11772 and EF-3221, LK-STO50, and MIVOLT-DFK) are evaluated as heat transfer fluids (HTFs) and compared with air and deionised water as benchmark.Additionally, the effects of heat pipe diameters (4 mm, 6 mm, and 8 mm) and the number of fins (1, 2, 3, and 5) are analysed for two configurations: fins evenly distributed along the heat pipe and fins placed only on the upper half.A 3D steady-state CFD model is developed in Ansys 2024R2 to simulate the proposed TMS for a 4S4P (14.8V, 10 Ah) Lithium-Nickel Manganese Cobalt (NMC) battery pack.Under typical 2C discharge rate, the model examines the TMS thermal performance when simulating heat transfer with and without buoyancy effects.Buoyancy improves cooling performance, especially for viscous fluids, lowering battery, HTF, and heat sink temperatures by 20%.With modest LIB heat generation rates (up to 25 kW/m), the TMS ensures effective cooling with minimum temperature increase.However, when reaching heat generation rates up to 100 kW/m, the battery temperature reaches 91.13C, revealing the system's cooling capability limitations.The study examines the effect of changing heat sink and insulation equivalent convective heat transfer coefficients.Increasing the heat sink coefficient from 10 to 100 W/mK lowers the battery temperature from 138C to 49C, while increasing the insulation equivalent heat transfer coefficient from 1 to 50 W/mK lowers battery temperature from 92C to 46C.Also, the effect of heat pipes diameter and fins number and vertical distribution is analysed, pointing to the design with 5 evenly distributed fins to be the best thermally performing while limiting additional TMS mass.This study shows that the hybrid TMS using heat pipes, fins, immersion cooling improves compact LEV safety, performance, and battery longevity under high-demand situations.

Journal of Fluid Flow Heat and Mass TransferVol. 12
Affordable and clean energy
Openalex Percentile: Top 87%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.