Effects of geometrical parameters on hemodynamics of arteriovenous graft: A 3D numerical simulation

Although arteriovenous grafts (AVGs) serve as a significant long-term hemodialysis access, they encounter issues such as stenosis, thrombosis, and potential graft failure. This study utilizes computational fluid dynamics to examine various combinations of geometric parameters in AVG design. Twelve looped AVG configurations are generated, including two representing commercially available AVGs. These models vary in length (60mm and 150mm), diameter (4mm, 5mm, and 6mm), and venous anastomosis (VA) angles (30º and 60º). A time-dependent velocity waveform is applied at the artery inlet, with rigid walls and non-Newtonian blood modeling. AVG performance is assessed using velocity, streamlines, graft flow, and wall shear stress metrics, such as time-averaged wall shear stress, oscillatory shear index, and relative residence time. Comparative analysis identifies an AVG with a 60 mm length, 5mm diameter, and 30º VA angle as a promising alternative to conventional graft configurations. This model demonstrates approximately 50% less exposure to unfavorable hemodynamics, with a marginal decrease of around 9% in maximum graft flow compared to commercial models. Shorter graft lengths, smaller diameters, and relatively smaller VA angles contribute to improved hemodynamic distribution. These findings offer insights applicable to clinical research on arteriovenous grafts and aid in developing effective therapeutic strategies. • Arteriovenous graft length and diameter significantly influences its hemodynamics • Short access grafts can supply sufficient blood flow for hemodialysis • Recirculation flow and high wall shear stress should be avoided at anastomoses

Authors

Institutions

Publication Details

Journal
Medicine in Novel Technology and Devices
Published
2025-06-11
DOI
https://doi.org/10.1016/j.medntd.2025.100376
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of geometrical parameters on hemodynamics of arteriovenous graft: A 3D numerical simulation

Aisa Rassoli, Majid Assadi
Medicine in Novel Technology and Devices
Coronary Interventions and Diagnostics
article

Effects of geometrical parameters on hemodynamics of arteriovenous graft: A 3D numerical simulation

Aisa Rassoli, Majid Assadi
article en

Abstract

Although arteriovenous grafts (AVGs) serve as a significant long-term hemodialysis access, they encounter issues such as stenosis, thrombosis, and potential graft failure. This study utilizes computational fluid dynamics to examine various combinations of geometric parameters in AVG design. Twelve looped AVG configurations are generated, including two representing commercially available AVGs. These models vary in length (60mm and 150mm), diameter (4mm, 5mm, and 6mm), and venous anastomosis (VA) angles (30º and 60º). A time-dependent velocity waveform is applied at the artery inlet, with rigid walls and non-Newtonian blood modeling. AVG performance is assessed using velocity, streamlines, graft flow, and wall shear stress metrics, such as time-averaged wall shear stress, oscillatory shear index, and relative residence time. Comparative analysis identifies an AVG with a 60 mm length, 5mm diameter, and 30º VA angle as a promising alternative to conventional graft configurations. This model demonstrates approximately 50% less exposure to unfavorable hemodynamics, with a marginal decrease of around 9% in maximum graft flow compared to commercial models. Shorter graft lengths, smaller diameters, and relatively smaller VA angles contribute to improved hemodynamic distribution. These findings offer insights applicable to clinical research on arteriovenous grafts and aid in developing effective therapeutic strategies. • Arteriovenous graft length and diameter significantly influences its hemodynamics • Short access grafts can supply sufficient blood flow for hemodialysis • Recirculation flow and high wall shear stress should be avoided at anastomoses

Medicine in Novel Technology and DevicesVol. 27
K. N. Toosi University of Technology (IR)
Openalex Percentile: Top 77%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of geometrical parameters on hemodynamics of arteriovenous graft: A 3D numerical simulation — Aisa Rassoli, Majid Assadi · Medicine in Novel Technology and Devices (2025) | TGRS Research Map | TGRS