pH-dependent performance of alkaline electrolyzed water concrete: A comprehensive analysis of strength, durability, and microstructural evolution

Aiming to address the environmental burdens and CO 2 emission issues caused by high cement clinker content in concrete, this study proposes a new approach for cement reduction in concrete through high active alkaline electrolyzed water (AEW) technology. In this study, through systematic design of three pH-gradient AEW systems (9.0, 10.0, and 11.0), the influences of AEW with different pH values on the mechanical properties, durability, and microstructural characteristics of concrete were investigated. The results showed that three AEWs accelerated cement hydration, evidenced by 23-min and 11-min reductions in initial and final setting times compared to NTW. Microstructural analyses indicated accelerated formation of cement hydration products in AEW systems, attributed to enhanced ionic activity, though pH variations exhibited little differential effects. AEW concrete demonstrated superior early-stage mechanical properties (optimal at pH value of 10.0), the strengths of AEW group increased by 10 % at 3 days and 8.5 % at 28 days than control group, with decreased growth rate during later curing stages. A lower cumulative mercury intrusion in AEW specimens verified microstructural densification through additional hydration product formation. Although the performance changes between AEW concrete with different pH values are still not significant, the synergistic effects of AEW's ionic adsorption and OH − cluster permeability were considered as critical mechanisms, collectively improve the mechanical strength, and durability of AEW concrete, which can leads to a reduction in cement clinker content and CO 2 emissions for AEW concrete. The findings can provide a scientific foundation for the engineering promotion and application of AEW-based low-carbon concrete.

Authors

Institutions

Publication Details

Journal
Journal of Materials Research and Technology
Published
2025-06-11
DOI
https://doi.org/10.1016/j.jmrt.2025.06.069
Citations
3
Primary Topic
Building materials and conservation
Type
article
Field-Weighted Citation Impact
5.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

pH-dependent performance of alkaline electrolyzed water concrete: A comprehensive analysis of strength, durability, and microstructural evolution

Fei Zhao, Zhen Zhu, Yanjun Wang, Meinan Wang et al.
3 citations
Journal of Materials Research and Technology
Building materials and conservation
5.01
article

pH-dependent performance of alkaline electrolyzed water concrete: A comprehensive analysis of strength, durability, and microstructural evolution

Fei Zhao, Zhen Zhu, Yanjun Wang, Meinan Wang, Honghui Xu, Mingxu Chen, Liang Wang, Chunyu Ma, Dongmei Wu
article en
3 citations

Abstract

Aiming to address the environmental burdens and CO 2 emission issues caused by high cement clinker content in concrete, this study proposes a new approach for cement reduction in concrete through high active alkaline electrolyzed water (AEW) technology. In this study, through systematic design of three pH-gradient AEW systems (9.0, 10.0, and 11.0), the influences of AEW with different pH values on the mechanical properties, durability, and microstructural characteristics of concrete were investigated. The results showed that three AEWs accelerated cement hydration, evidenced by 23-min and 11-min reductions in initial and final setting times compared to NTW. Microstructural analyses indicated accelerated formation of cement hydration products in AEW systems, attributed to enhanced ionic activity, though pH variations exhibited little differential effects. AEW concrete demonstrated superior early-stage mechanical properties (optimal at pH value of 10.0), the strengths of AEW group increased by 10 % at 3 days and 8.5 % at 28 days than control group, with decreased growth rate during later curing stages. A lower cumulative mercury intrusion in AEW specimens verified microstructural densification through additional hydration product formation. Although the performance changes between AEW concrete with different pH values are still not significant, the synergistic effects of AEW's ionic adsorption and OH − cluster permeability were considered as critical mechanisms, collectively improve the mechanical strength, and durability of AEW concrete, which can leads to a reduction in cement clinker content and CO 2 emissions for AEW concrete. The findings can provide a scientific foundation for the engineering promotion and application of AEW-based low-carbon concrete.

Journal of Materials Research and TechnologyVol. 37
Qingdao Agricultural University (CN), Beijing Urban Construction Design & Development Group (China) (CN), China Railway Construction Corporation (China) (CN), China Railway Group (China) (CN), Qingdao University of Technology (CN)
Openalex Percentile: Top 5%
Building materials and conservation
5.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.