ALTERNATIVE SEISMIC DESIGN OF MULTI STOREY TIMBER STRUCTURES

Research on the structural response of large, multi-story timber buildings under horizontal loading conditions, such as wind and earthquakes, remains limited in the current literature. In particular, there is a need for improved understanding of the nonlinear behavior of these structures and how energy dissipation mechanisms influence their seismic performance. This study focuses on nonlinear time history analysis of multi-storey timber buildings, emphasizing the role re-centering mechanism in the seismic response. A set of 3D timber building configurations was designed according to Eurocode force-based design principles and subsequently evaluated using nonlinear dynamic simulations. The results show that the early stage design choices, such as how the vertical load will be distributed, whether the CLT walls will contribute to that or not, and whether a self-centering mechanism will be used, can fundamentally change the overall seismic behavior of the structure in the non-linear phase. Key insights are summarized regarding the weight acting on the CLT walls in relation to two common hold-down response mechanisms, elastic-perfectly-plastic self-centering.

Authors

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.52202/080513-0528
Primary Topic
Structural Analysis and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ALTERNATIVE SEISMIC DESIGN OF MULTI STOREY TIMBER STRUCTURES

Stylianos Kallioras, Kadir Özdemir, Costanza Maria Russo, Eleni Smyrou et al.
Structural Analysis and Optimization
article

ALTERNATIVE SEISMIC DESIGN OF MULTI STOREY TIMBER STRUCTURES

Stylianos Kallioras, Kadir Özdemir, Costanza Maria Russo, Eleni Smyrou, İhsan Engin Bal
article en

Abstract

Research on the structural response of large, multi-story timber buildings under horizontal loading conditions, such as wind and earthquakes, remains limited in the current literature. In particular, there is a need for improved understanding of the nonlinear behavior of these structures and how energy dissipation mechanisms influence their seismic performance. This study focuses on nonlinear time history analysis of multi-storey timber buildings, emphasizing the role re-centering mechanism in the seismic response. A set of 3D timber building configurations was designed according to Eurocode force-based design principles and subsequently evaluated using nonlinear dynamic simulations. The results show that the early stage design choices, such as how the vertical load will be distributed, whether the CLT walls will contribute to that or not, and whether a self-centering mechanism will be used, can fundamentally change the overall seismic behavior of the structure in the non-linear phase. Key insights are summarized regarding the weight acting on the CLT walls in relation to two common hold-down response mechanisms, elastic-perfectly-plastic self-centering.

Sustainable cities and communities
Openalex Percentile: Top 86%
Structural Analysis and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.