Radiological safety assessment for water treatment facility due to radon inhalation in Korea

Water treatment facilities are facilities that use groundwater to produce potable water. Groundwater can contain radon which is a naturally occurring radionuclide, and water treatment facility workers who directly handle groundwater are at risk of internal exposure from radon inhalation. The objective of this study is to assess the internal radiation dose from radon inhalation in water treatment facility workers in Korea. To achieve this, we analyzed work processes in 6 water treatment facilities in Korea, and main process areas were investigated through interviews with workers. The airborne radon concentration was measured in the main process areas using the RAD 7 and Raduet radon detector. Radon concentrations measured in the main process areas ranged from 16.6 to 756 Bq m −3 , which is below the ICRP's reference level of 1,000 Bq m −3 . The internal radiation dose due to radon inhalation ranged from 0.193 to 5.80 mSv y −1 . This is about half of the ICRP's reference level of 10 mSv y −1 for radon inhalation. This study can be used as technical data for radiological safety management of NORM industries in Korea.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-06-11
DOI
https://doi.org/10.1016/j.net.2025.103727
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiological safety assessment for water treatment facility due to radon inhalation in Korea

Shin Dong Lee, Kwang Pyo Kim, Jeong Woo Lee, Chang Hee Han et al.
Nuclear Engineering and Technology
Radioactivity and Radon Measurements
article

Radiological safety assessment for water treatment facility due to radon inhalation in Korea

Shin Dong Lee, Kwang Pyo Kim, Jeong Woo Lee, Chang Hee Han, Seung Beom Yoo
article en

Abstract

Water treatment facilities are facilities that use groundwater to produce potable water. Groundwater can contain radon which is a naturally occurring radionuclide, and water treatment facility workers who directly handle groundwater are at risk of internal exposure from radon inhalation. The objective of this study is to assess the internal radiation dose from radon inhalation in water treatment facility workers in Korea. To achieve this, we analyzed work processes in 6 water treatment facilities in Korea, and main process areas were investigated through interviews with workers. The airborne radon concentration was measured in the main process areas using the RAD 7 and Raduet radon detector. Radon concentrations measured in the main process areas ranged from 16.6 to 756 Bq m −3 , which is below the ICRP's reference level of 1,000 Bq m −3 . The internal radiation dose due to radon inhalation ranged from 0.193 to 5.80 mSv y −1 . This is about half of the ICRP's reference level of 10 mSv y −1 for radon inhalation. This study can be used as technical data for radiological safety management of NORM industries in Korea.

Nuclear Engineering and TechnologyVol. 57(10)
Kyung Hee University (KR)
Korea Foundation, Nuclear Safety and Security Commission
Clean water and sanitation
Openalex Percentile: Top 82%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Radiological safety assessment for water treatment facility due to radon inhalation in Korea — Shin Dong Lee, Kwang Pyo Kim, et al. · Nuclear Engineering and Technology (2025) | TGRS Research Map | TGRS