Power operation region modeling and transient overvoltage suppression strategy of hybrid cascaded HVDC

• A method for calculating transient overvoltage in HC-HVDC during CF is proposed. • The mechanisms and key factors of transient overvoltage in HC-HVDC are clarified. • An operation region for active and reactive power in HC-HVDC is established. • A TOV suppression strategy based on power operation region is proposed. The hybrid cascaded HVDC system(HC-HVDC) in sending end system is composed of an Line Commutated Converter(LCC) connected in series with a parallel group of Modular Multilevel Converters (MMC). This system offers high flexibility and strong adaptability to weak systems. However, since the commutation failure (CF) is easy to occur at the inverter side in the LCC, which can lead to the transient overvoltage at the rectifier side. The mechanism and voltage characteristics of the transient overvoltage are not yet clear. To handle this problem, firstly, the mechanism of transient overvoltage caused by CF is analyzed. Then, the power operation region of the sending end HC-HVDC considering transient overvoltage constraints is established. Based on this analysis, a transient overvoltage suppression strategy is proposed. It determines the increment in reactive power consumption of MMC and LCC based on different power operating points. The reactive power surplus at the sending end system can be reduced, and the transient overvoltage can be suppressed. Finally, a simulation model in PSCAD/EMTDC platform to verify the mechanism of transient overvoltage and the transient overvoltage suppression effect of the proposed strategy in the situation of different fault types, fault duration, fault severity and short circuit ratio is verified.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-06-11
DOI
https://doi.org/10.1016/j.ijepes.2025.110803
Citations
4
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
2.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power operation region modeling and transient overvoltage suppression strategy of hybrid cascaded HVDC

Chunya Yin, Ruikang Chen, Jiangshan Liu, Yingping Shi et al.
4 citations
International Journal of Electrical Power & Energy Systems
HVDC Systems and Fault Protection
2.92
article

Power operation region modeling and transient overvoltage suppression strategy of hybrid cascaded HVDC

Chunya Yin, Ruikang Chen, Jiangshan Liu, Yingping Shi, Lu Han, Fengting Li
article en
4 citations

Abstract

• A method for calculating transient overvoltage in HC-HVDC during CF is proposed. • The mechanisms and key factors of transient overvoltage in HC-HVDC are clarified. • An operation region for active and reactive power in HC-HVDC is established. • A TOV suppression strategy based on power operation region is proposed. The hybrid cascaded HVDC system(HC-HVDC) in sending end system is composed of an Line Commutated Converter(LCC) connected in series with a parallel group of Modular Multilevel Converters (MMC). This system offers high flexibility and strong adaptability to weak systems. However, since the commutation failure (CF) is easy to occur at the inverter side in the LCC, which can lead to the transient overvoltage at the rectifier side. The mechanism and voltage characteristics of the transient overvoltage are not yet clear. To handle this problem, firstly, the mechanism of transient overvoltage caused by CF is analyzed. Then, the power operation region of the sending end HC-HVDC considering transient overvoltage constraints is established. Based on this analysis, a transient overvoltage suppression strategy is proposed. It determines the increment in reactive power consumption of MMC and LCC based on different power operating points. The reactive power surplus at the sending end system can be reduced, and the transient overvoltage can be suppressed. Finally, a simulation model in PSCAD/EMTDC platform to verify the mechanism of transient overvoltage and the transient overvoltage suppression effect of the proposed strategy in the situation of different fault types, fault duration, fault severity and short circuit ratio is verified.

International Journal of Electrical Power & Energy SystemsVol. 169
Xinjiang University (CN)
Key Technologies Research and Development Program, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 9%
HVDC Systems and Fault Protection
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.