Concurrent analysis of six NSAIDs in human plasma using polyurethane/B–N–S-co-doped rGO nanofiber-modified glassy carbon electrode followed by EA-SPME

Herein, a novel voltammetric biosensor was designed and constructed for the simultaneous measurement of six nonsteroidal anti-inflammatory drugs (NSAIDs), including celecoxib, mefenamic acid, acetaminophen, naproxen, ibuprofen, and caffeine. In this biosensor, the glassy carbon electrode (GCE) was used as an unmodified working electrode. For modification, the water based-polyurethane-(B-N-S)-co doped-rGO electrospun nanofibers (WB-PU-(B-N-S)-rGO NFs) were first collected on the conductive surface of GCE. Subsequently, the biosensor was used to analyze the presence of six NSAIDs in human plasma samples. Prior to this analysis, the plasma samples were prepared using electrospun nanofibers made of polyvinyl alcohol/casein/tannic acid/polyaniline/titanium dioxide nanoparticles (PVA/CAS/TA/PANI/TiO<sub>2</sub> NPs) in electrically assisted solid phase microextraction (EA-SPME) on a pewter rod. The WB-PU-(B-N-S)-rGO NFs were characterized with Fourier transform-infrared (FT-IR), field emission-scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy with elemental mapping analysis (EDS-Mapping), and X-ray diffraction (XRD), which confirmed the synthesis of this nanocomposite. According to optimum conditions, the wide linear range was 30-900 μM with <i>R</i><sup>2</sup> ≥ 0.9585, and low detection limits ranged from 8.6 to 47.5 μM based on S/N = 3. The intra-day and inter-day RSDs% were obtained within 4.17-4.90% and 4.92-5.49%, respectively. Finally, the efficiency of the electrochemical biosensor was evaluated to determine these six NSAIDs in human plasma samples with good recoveries (91.0-102.8%).

Authors

Institutions

Publication Details

Journal
Journal of Materials Chemistry B
Published
2025-01-01
DOI
https://doi.org/10.1039/d5tb00847f
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concurrent analysis of six NSAIDs in human plasma using polyurethane/B–N–S-co-doped rGO nanofiber-modified glassy carbon electrode followed by EA-SPME

Fatemeh Nejabati, Homeira Ebrahimzadeh
Journal of Materials Chemistry B
Electrochemical sensors and biosensors
article

Concurrent analysis of six NSAIDs in human plasma using polyurethane/B–N–S-co-doped rGO nanofiber-modified glassy carbon electrode followed by EA-SPME

Fatemeh Nejabati, Homeira Ebrahimzadeh
article en

Abstract

Herein, a novel voltammetric biosensor was designed and constructed for the simultaneous measurement of six nonsteroidal anti-inflammatory drugs (NSAIDs), including celecoxib, mefenamic acid, acetaminophen, naproxen, ibuprofen, and caffeine. In this biosensor, the glassy carbon electrode (GCE) was used as an unmodified working electrode. For modification, the water based-polyurethane-(B-N-S)-co doped-rGO electrospun nanofibers (WB-PU-(B-N-S)-rGO NFs) were first collected on the conductive surface of GCE. Subsequently, the biosensor was used to analyze the presence of six NSAIDs in human plasma samples. Prior to this analysis, the plasma samples were prepared using electrospun nanofibers made of polyvinyl alcohol/casein/tannic acid/polyaniline/titanium dioxide nanoparticles (PVA/CAS/TA/PANI/TiO<sub>2</sub> NPs) in electrically assisted solid phase microextraction (EA-SPME) on a pewter rod. The WB-PU-(B-N-S)-rGO NFs were characterized with Fourier transform-infrared (FT-IR), field emission-scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy with elemental mapping analysis (EDS-Mapping), and X-ray diffraction (XRD), which confirmed the synthesis of this nanocomposite. According to optimum conditions, the wide linear range was 30-900 μM with <i>R</i><sup>2</sup> ≥ 0.9585, and low detection limits ranged from 8.6 to 47.5 μM based on S/N = 3. The intra-day and inter-day RSDs% were obtained within 4.17-4.90% and 4.92-5.49%, respectively. Finally, the efficiency of the electrochemical biosensor was evaluated to determine these six NSAIDs in human plasma samples with good recoveries (91.0-102.8%).

Journal of Materials Chemistry BVol. 13(30)
Shahid Beheshti University (IR)
Shahid Beheshti University
Openalex Percentile: Top 89%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Concurrent analysis of six NSAIDs in human plasma using polyurethane/B–N–S-co-doped rGO nanofiber-modified glassy carbon electrode followed by EA-SPME — Fatemeh Nejabati, Homeira Ebrahimzadeh · Journal of Materials Chemistry B (2025) | TGRS Research Map | TGRS