Enhanced Techniques for Cardiac Signal Processing in Continuous Daily Monitoring Systems

For continuous cardiac assessment, electrocardiographic (ECG) monitoring in wearable and ambulatory settings is becoming more and more important.However, it is still susceptible to a number of noise sources, including baseline drift, motion artifacts, electromagnetic interference (EMI), and muscle activity (EMG).P-waves, the QRS complex, and ST segments are examples of diagnostically important characteristics that may be obscured by these interferences.The non-adaptive, phasedistorting, and morphology-blurring characteristics of classical filters frequently lead to their failure.To address this, we suggest a dual-filter adaptive denoising pipeline that combines a locally adaptive Wiener filter with a modified Savitzky-Golay filter.Using statistical variance estimations and spectral flatness criteria, our method dynamically adjusts to spectral features and signal shape, preserving important cardiac fingerprints while reducing noise.In-depth MATLAB simulations show increases in signal-to-noise ratio (SNR) of 6-8 dB and a 47.5% decrease in root mean square error (RMSE), while preserving over 90% QRS fidelity across 14 different noise circumstances.Theoretical advances in signal processing and real-time cardiac diagnostics are connected in this work.

Authors

Publication Details

Journal
SCIENTIFIC WORK
Published
2025-05-31
DOI
https://doi.org/10.36719/2663-4619/117/110-113
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Techniques for Cardiac Signal Processing in Continuous Daily Monitoring Systems

Nuraddin Aliyev
SCIENTIFIC WORK
Non-Invasive Vital Sign Monitoring
article

Enhanced Techniques for Cardiac Signal Processing in Continuous Daily Monitoring Systems

Nuraddin Aliyev
article en

Abstract

For continuous cardiac assessment, electrocardiographic (ECG) monitoring in wearable and ambulatory settings is becoming more and more important.However, it is still susceptible to a number of noise sources, including baseline drift, motion artifacts, electromagnetic interference (EMI), and muscle activity (EMG).P-waves, the QRS complex, and ST segments are examples of diagnostically important characteristics that may be obscured by these interferences.The non-adaptive, phasedistorting, and morphology-blurring characteristics of classical filters frequently lead to their failure.To address this, we suggest a dual-filter adaptive denoising pipeline that combines a locally adaptive Wiener filter with a modified Savitzky-Golay filter.Using statistical variance estimations and spectral flatness criteria, our method dynamically adjusts to spectral features and signal shape, preserving important cardiac fingerprints while reducing noise.In-depth MATLAB simulations show increases in signal-to-noise ratio (SNR) of 6-8 dB and a 47.5% decrease in root mean square error (RMSE), while preserving over 90% QRS fidelity across 14 different noise circumstances.Theoretical advances in signal processing and real-time cardiac diagnostics are connected in this work.

SCIENTIFIC WORKVol. Special(Issue 3)
Openalex Percentile: Top 88%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced Techniques for Cardiac Signal Processing in Continuous Daily Monitoring Systems — Nuraddin Aliyev · SCIENTIFIC WORK (2025) | TGRS Research Map | TGRS