Ves-GAN: Unsupervised Vessel-Targeted Low-Dose Coronary Computed Tomography Angiography Denoising Framework

<b>Objective:</b> This study aims to develop an unsupervised denoising framework for low-dose coronary computed tomography (CT) angiography (LDCTA), which reduces noise while preserving vascular structures. <b>Impact Statement:</b> This work proposes Ves-GAN, a novel denoising framework that meets the challenges of data acquisition and assumptions about noise characteristics. By providing robust noise reduction while maintaining vascular integrity, Ves-GAN facilitates more reliable clinical evaluations and improves the overall quality of cardiovascular diagnosis. <b>Introduction:</b> LDCTA minimizes radiation exposure in cardiovascular imaging but introduces noise and blurring, affecting diagnostic accuracy. Existing denoising methods, such as supervised deep learning models, require paired datasets and rely on noise assumptions. Unsupervised models show promise but often fail to preserve vascular structures, limiting clinical application. <b>Methods:</b> Ves-GAN incorporates a high-frequency-aware data augmentation strategy for robust generalization. The generator employs a high-frequency squeeze-and-excitation module to improve sensitivity to fine vascular features. Additionally, a vessel-consistency loss is introduced to preserve structural integrity during the denoising process. <b>Results:</b> On average, Ves-GAN achieves 7.5% and 10.2% improvements in peak signal-to-noise ratio and structural similarity index metrics compared to existing unsupervised models. Clinical validation involved 50 CT scans reviewed by 3 radiologists, who noted substantial enhancements in vascular clarity and lesion visibility. <b>Conclusion:</b> Ves-GAN outperforms existing unsupervised models in preserving vascular details and noise reduction, significantly enhancing clinical diagnostic reliability.

Authors

Institutions

Publication Details

Journal
BME Frontiers
Published
2025-01-01
DOI
https://doi.org/10.34133/bmef.0149
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ves-GAN: Unsupervised Vessel-Targeted Low-Dose Coronary Computed Tomography Angiography Denoising Framework

Xiaohe Chen, Xinyuan Xiang, Yan Yi, Sixing Yin et al.
BME Frontiers
Advanced X-ray and CT Imaging
article

Ves-GAN: Unsupervised Vessel-Targeted Low-Dose Coronary Computed Tomography Angiography Denoising Framework

Xiaohe Chen, Xinyuan Xiang, Yan Yi, Sixing Yin, Jiayue Li, Yining Wang
article en

Abstract

<b>Objective:</b> This study aims to develop an unsupervised denoising framework for low-dose coronary computed tomography (CT) angiography (LDCTA), which reduces noise while preserving vascular structures. <b>Impact Statement:</b> This work proposes Ves-GAN, a novel denoising framework that meets the challenges of data acquisition and assumptions about noise characteristics. By providing robust noise reduction while maintaining vascular integrity, Ves-GAN facilitates more reliable clinical evaluations and improves the overall quality of cardiovascular diagnosis. <b>Introduction:</b> LDCTA minimizes radiation exposure in cardiovascular imaging but introduces noise and blurring, affecting diagnostic accuracy. Existing denoising methods, such as supervised deep learning models, require paired datasets and rely on noise assumptions. Unsupervised models show promise but often fail to preserve vascular structures, limiting clinical application. <b>Methods:</b> Ves-GAN incorporates a high-frequency-aware data augmentation strategy for robust generalization. The generator employs a high-frequency squeeze-and-excitation module to improve sensitivity to fine vascular features. Additionally, a vessel-consistency loss is introduced to preserve structural integrity during the denoising process. <b>Results:</b> On average, Ves-GAN achieves 7.5% and 10.2% improvements in peak signal-to-noise ratio and structural similarity index metrics compared to existing unsupervised models. Clinical validation involved 50 CT scans reviewed by 3 radiologists, who noted substantial enhancements in vascular clarity and lesion visibility. <b>Conclusion:</b> Ves-GAN outperforms existing unsupervised models in preserving vascular details and noise reduction, significantly enhancing clinical diagnostic reliability.

BME FrontiersVol. 6
Beijing University of Posts and Telecommunications (CN), North China University of Technology (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), China University of Petroleum, Beijing (CN), Peking Union Medical College Hospital (CN), Beijing Academy of Artificial Intelligence (CN)
Natural Science Foundation of Beijing Municipality
Openalex Percentile: Top 88%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.